Publications

Detailed Information

건물 에너지 절약을 위한 저류 옥상 녹화의 온도 저감 효과 : The effect of Temperature Reduction of Green roof for building energy-saving using Rainwater Storage Tank

DC Field Value Language
dc.contributor.author윤석환-
dc.contributor.author김은섭-
dc.contributor.author박정강-
dc.contributor.author김상혁-
dc.contributor.author김나연-
dc.contributor.author황혜미-
dc.contributor.author제상우-
dc.contributor.author강한민-
dc.contributor.author함은경-
dc.contributor.author이동근-
dc.date.accessioned2024-04-24T02:29:17Z-
dc.date.available2024-04-24T02:29:17Z-
dc.date.created2024-04-16-
dc.date.issued2023-08-
dc.identifier.citation한국환경복원기술학회지, Vol.26 No.4, pp.51-59-
dc.identifier.issn1229-3032-
dc.identifier.urihttps://hdl.handle.net/10371/199286-
dc.description.abstractDespite countries' efforts to reduce carbon emissions, carbon emissions have increased in recent decades along with energy use, of which building energy uses account for a large proportion. Energy savings are essential as a strategy to reduce carbon emissions in existing buildings. The field experiment on the roof of a building located in Seoul was designed to measure the temperature reduction effect of green roof with rainwater storage tank to reduce cooling energy consumption in summer. The results showed that the mean mean surface temperature under the green roof was 14.77 degrees lower than that of the non-green roof from 13:00 P.M. to 15:00 P.M., which would have a great effect on reducing cooling energy. From 01:00 A.M. to 03:00 A.M., the effect was 3.36 degrees, showing that tropical nights could be improved. The temperature reduction effect due to the rainwater storage system increased by 1.45 degrees during the day and decreased by 0.63 degrees at night. The storage system can be strategically utilized to reduce carbon emissions during the week when cooling energy increases significantly.-
dc.language한국어-
dc.publisher한국환경복원기술학회-
dc.title건물 에너지 절약을 위한 저류 옥상 녹화의 온도 저감 효과-
dc.title.alternativeThe effect of Temperature Reduction of Green roof for building energy-saving using Rainwater Storage Tank-
dc.typeArticle-
dc.citation.journaltitle한국환경복원기술학회지-
dc.citation.endpage59-
dc.citation.number4-
dc.citation.startpage51-
dc.citation.volume26-
dc.identifier.kciidART002993782-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthor이동근-
dc.description.journalClass2-
dc.subject.keywordAuthorEnergy consumption-
dc.subject.keywordAuthorEnergy saving-
dc.subject.keywordAuthorCarbon emissions-
dc.subject.keywordAuthorUrban planning-
dc.subject.keywordAuthorEnvironmental planning-
dc.subject.keywordAuthorurban greening strategy-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share