Publications

Detailed Information

Low Bone Density Predictability of CBCT and Its Relation to Primary Stability of Tapered Implant Design: A Pilot Study

DC Field Value Language
dc.contributor.authorLee, Sang Hoon-
dc.contributor.authorYun, Pil Young-
dc.contributor.authorYi, Yang Jin-
dc.contributor.authorKim, Young Kyun-
dc.contributor.authorLee, Hyo Jung-
dc.contributor.authorJo, Deuk Won-
dc.date.accessioned2024-05-01T01:28:10Z-
dc.date.available2024-05-01T01:28:10Z-
dc.date.created2024-04-30-
dc.date.issued2023-10-
dc.identifier.citationThe Journal of oral implantology, Vol.49 No.5, pp.556-563-
dc.identifier.issn0160-6972-
dc.identifier.urihttps://hdl.handle.net/10371/200054-
dc.description.abstractResearch regarding bone density assessment using cone beam computed tomography (CBCT) in low bone density regions is sparse. This in vitro study aimed to evaluate the predictability of CBCT for low bone density regions and its correlations with primary implant stability when placing tapered design implants with a stepped osteotomy. Eighteen porcine mandibular condyles were used as simulated low bone density regions. Hounsfield units (HU), obtained via multislice computed tomography, and gray values (GVs), obtained via CBCT, were measured 3 times at 1-month intervals. The maximum implant insertion torque (MIT) and implant stability quotient (ISQ) were recorded as the taper design implants were placed using a stepped osteotomy. Hounsfield units and GV were measured as 335.05-803.07 and 389.98-906.40, respectively. For repeated measurements of HU and GV, the intraclass correlation coefficients were 0.989 and 0.980; the corresponding value for mean HU and GV was 0.768. Bland-Altman plots showed a mean difference between HU and GV of -78.15. Pearson correlation coefficients revealed a strong correlation between HU and GV (r = 0.91, P , .01). The mean +/- SD values for MIT and ISQ were 36.44 +/- 6.64 Ncm and 80.85 +/- 2.03, respectively, but no statistically significant correlations were found with GV and HU. Within the study's limitations, GV showed similar bone density estimation compared with HU in soft bones. Tapered implant placement with a stepped osteotomy achieved stable primary implant stability in soft bones. However, these in vitro results need to be approved in further clinical studies.-
dc.language영어-
dc.publisherAllen Press Inc.-
dc.titleLow Bone Density Predictability of CBCT and Its Relation to Primary Stability of Tapered Implant Design: A Pilot Study-
dc.typeArticle-
dc.identifier.doi10.1563/aaid-joi-D-21-00159-
dc.citation.journaltitleThe Journal of oral implantology-
dc.identifier.wosid001184389100010-
dc.identifier.scopusid2-s2.0-85185008352-
dc.citation.endpage563-
dc.citation.number5-
dc.citation.startpage556-
dc.citation.volume49-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorYun, Pil Young-
dc.contributor.affiliatedAuthorYi, Yang Jin-
dc.contributor.affiliatedAuthorKim, Young Kyun-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusBEAM COMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusINSERTION TORQUE-
dc.subject.keywordPlusDENTAL IMPLANTS-
dc.subject.keywordPlusFORMATION ADJACENT-
dc.subject.keywordPlusSTEPPED OSTEOTOMY-
dc.subject.keywordPlusDRILLING PROTOCOL-
dc.subject.keywordPlusSITES-
dc.subject.keywordPlusQUALITY-
dc.subject.keywordPlusVALUES-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordAuthorlow bone density-
dc.subject.keywordAuthorcone beam computed tomography-
dc.subject.keywordAuthorimplant stability-
dc.subject.keywordAuthortapered implant design-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

Yun, Pil Young Image

Yun, Pil Young윤필영
(기금)부교수
  • School of Dentistry
  • Department of Dentistry
Research Area Dentistry, Oral Pathology, Oral and Maxillofacial Surgery, 구강병리학, 구강악안면외과학, 치의학

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share