Publications

Detailed Information

A clinical pilot study of jawbone mineral density measured by the newly developed dual-energy cone-beam computed tomography method compared to calibrated multislice computed tomography

DC Field Value Language
dc.contributor.authorKim, Hyun Jeong-
dc.contributor.authorKim, Ji Eun-
dc.contributor.authorChoo, Jiyeon-
dc.contributor.authorMin, Jeonghee-
dc.contributor.authorChang, Sungho-
dc.contributor.authorLee, Sang Chul-
dc.contributor.authorPyun, Woong Beom-
dc.contributor.authorSeo, Kwang-Suk-
dc.contributor.authorKarm, Myong-Hwan-
dc.contributor.authorKoo, Ki-Tae-
dc.contributor.authorRhyu, In-Chul-
dc.contributor.authorMyoung, Hoon-
dc.contributor.authorHeo, Min-Suk-
dc.date.accessioned2024-05-02T06:00:01Z-
dc.date.available2024-05-02T06:00:01Z-
dc.date.created2020-01-21-
dc.date.created2020-01-21-
dc.date.issued2019-12-
dc.identifier.citationImaging Science in Dentistry, Vol.49 No.4, pp.295-299-
dc.identifier.issn2233-7822-
dc.identifier.urihttps://hdl.handle.net/10371/200515-
dc.description.abstractPurpose: This clinical pilot study was performed to determine the effectiveness of dual-energy cone-beam computed tomography (DE-CBCT) in measuring bone mineral density (BMD). Materials and Methods: The BMD values obtained using DE-CBCT were compared to those obtained using calibrated multislice computed tomography (MSCT). After BMD calibration with specially designed phantoms, both DE-CBCT and MSCT scanning were performed in 15 adult dental patients. Three-dimensional (3D) Digital Imaging and Communications in Medicine data were imported into a dental software program, and the defined regions of interest (ROIs) on the 3-dimensional surface-rendered images were identified. The automatically-measured BMD values of the ROIs (g/cm(3)), the differences in the measured BMD values of the matched ROIs obtained by DE-CBCT and MSCT 3D images, and the correlation between the BMD values obtained by the 2 devices were statistically analyzed. Results: The mean BMD values of the ROIs for the 15 patients as assessed using DE-CBCT and MSCT were 1.09 +/- 0.07 g/cm(3) and 1.13 +/- 0.08 g/cm(3), respectively. The mean of the differences between the BMD values of the matched ROIs as assessed using DE-CBCT and calibrated MSCT images was 0.04 +/- 0.02 g/cm(3). The Pearson correlation coefficient between the BMD values of DE-CBCT and MSCT images was 0.982 (r = 0.982, P<0.001). Conclusion: The newly developed DE-CBCT technique could be used to measure jaw BMD in dentistry and may soon replace MSCT, which is expensive and requires special facilities.-
dc.language영어-
dc.publisher대한구강악안면방사선학회-
dc.titleA clinical pilot study of jawbone mineral density measured by the newly developed dual-energy cone-beam computed tomography method compared to calibrated multislice computed tomography-
dc.typeArticle-
dc.identifier.doi10.5624/isd.2019.49.4.295-
dc.citation.journaltitleImaging Science in Dentistry-
dc.identifier.wosid000505754200006-
dc.identifier.scopusid2-s2.0-85078800525-
dc.citation.endpage299-
dc.citation.number4-
dc.citation.startpage295-
dc.citation.volume49-
dc.identifier.kciidART002535787-
dc.description.isOpenAccessY-
dc.contributor.affiliatedAuthorKim, Hyun Jeong-
dc.contributor.affiliatedAuthorSeo, Kwang-Suk-
dc.contributor.affiliatedAuthorKarm, Myong-Hwan-
dc.contributor.affiliatedAuthorKoo, Ki-Tae-
dc.contributor.affiliatedAuthorRhyu, In-Chul-
dc.contributor.affiliatedAuthorMyoung, Hoon-
dc.contributor.affiliatedAuthorHeo, Min-Suk-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusDENTAL IMPLANT SITES-
dc.subject.keywordPlusBONE-DENSITY-
dc.subject.keywordPlusASSESSMENTS-
dc.subject.keywordAuthorBone Mineral Density-
dc.subject.keywordAuthorCone-Beam Computed Tomography-
dc.subject.keywordAuthorDual Energy-
dc.subject.keywordAuthorPhantoms-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

Karm, Myong-Hwan Image

Karm, Myong-Hwan감명환
(기금)조교수
  • School of Dentistry
  • Department of Dentistry
Research Area Dental Anesthesiology, Pain Control, 치과마취, 치과진정법, 통증조절

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share