Publications
Detailed Information
Evaluation of an automatic approach device to the epidural space of Beagle dogs
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rhee, Suehyung | - |
dc.contributor.author | Son, Won-Gyun | - |
dc.contributor.author | Kim, Dalhae | - |
dc.contributor.author | Shin, Donghwi | - |
dc.contributor.author | Kim, Jiyoung | - |
dc.contributor.author | Sung, Taehoon | - |
dc.contributor.author | Yoon, Sangjin | - |
dc.contributor.author | Lee, Inhyung | - |
dc.date.accessioned | 2024-05-08T01:32:55Z | - |
dc.date.available | 2024-05-08T01:32:55Z | - |
dc.date.created | 2023-07-19 | - |
dc.date.created | 2023-07-19 | - |
dc.date.issued | 2023-07 | - |
dc.identifier.citation | Veterinary Anaesthesia and Analgesia, Vol.50 No.4, pp.372-380 | - |
dc.identifier.issn | 1467-2987 | - |
dc.identifier.uri | https://hdl.handle.net/10371/201077 | - |
dc.description.abstract | Objective: To compare the epidural anesthesia device (EPIA), which facilitates an automatic approach to location of the epidural space, with the performance of clinicians using tactile sensation and differences in pressure when inserting an epidural needle into the epidural space of a dog. Study design: Prospective, crossover experiment. Animals: A total of 14 Beagle dogs weighing 7.5 ± 2.4 kg (mean ± standard deviation). Methods: Each dog was anesthetized three times at 2 week intervals for three anesthesiologists (two experienced, one novice) to perform 14 epidural injections (seven manual and EPIA device each). The sequence of methods was assigned randomly for each anesthesiologist. The dogs were anesthetized with medetomidine (10 μg kg–1), alfaxalone (2 mg kg–1) and isoflurane and positioned in sternal recumbency with the pelvic limbs extended cranially. Epidural puncture in the manual method was determined by pop sensation, hanging drop technique and reduced injection pressure, whereas using the device a sudden decrease in reaction force on the device was detected. A C-arm identified needle placement in the epidural space, and after administration of iohexol (0.3 mL), the needle length in the epidural space was defined as the mean value measured by three radiologists. Normality was tested using the Kolmogorov–Smirnov test, and significant differences between the two methods were analyzed using an independent sample t test. Results: In both methods, the success rates of epidural insertion were the same at 95.2%. The length of the needle in the epidural space using the device and manual methods was 1.59 ± 0.50 and 1.68 ± 0.88 mm, respectively, with no significant difference (p = 0.718). Conclusions and clinical relevance: EPIA device was comparable to human tactile sense for an epidural needle insertion in Beagle dogs. Further research should be conducted for application of the device in clinical environments. | - |
dc.language | 영어 | - |
dc.publisher | Blackwell Publishing Inc. | - |
dc.title | Evaluation of an automatic approach device to the epidural space of Beagle dogs | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.vaa.2023.04.005 | - |
dc.citation.journaltitle | Veterinary Anaesthesia and Analgesia | - |
dc.identifier.wosid | 001035585700001 | - |
dc.identifier.scopusid | 2-s2.0-85160855110 | - |
dc.citation.endpage | 380 | - |
dc.citation.number | 4 | - |
dc.citation.startpage | 372 | - |
dc.citation.volume | 50 | - |
dc.description.isOpenAccess | N | - |
dc.contributor.affiliatedAuthor | Son, Won-Gyun | - |
dc.contributor.affiliatedAuthor | Lee, Inhyung | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.subject.keywordPlus | ANALGESIA | - |
dc.subject.keywordPlus | BUPIVACAINE | - |
dc.subject.keywordPlus | PRESSURE | - |
dc.subject.keywordPlus | MORPHINE | - |
dc.subject.keywordAuthor | dogs | - |
dc.subject.keywordAuthor | EPIA | - |
dc.subject.keywordAuthor | epidural approach | - |
dc.subject.keywordAuthor | pop sensation | - |
dc.subject.keywordAuthor | reaction force | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.