Publications

Detailed Information

Evaluation of the tongue for oscillometric measurement of arterial pressure in anesthetized Beagle dogs

DC Field Value Language
dc.contributor.authorKim, Dalhae-
dc.contributor.authorKim, Hyunseok-
dc.contributor.authorShin, Donghwi-
dc.contributor.authorKim, Jiyoung-
dc.contributor.authorLee, Inhyung-
dc.contributor.authorSon, Won-gyun-
dc.date.accessioned2024-05-08T01:33:38Z-
dc.date.available2024-05-08T01:33:38Z-
dc.date.created2022-04-28-
dc.date.created2022-04-28-
dc.date.issued2022-03-
dc.identifier.citationVeterinary Anaesthesia and Analgesia, Vol.49 No.2, pp.149-155-
dc.identifier.issn1467-2987-
dc.identifier.urihttps://hdl.handle.net/10371/201089-
dc.description.abstract© 2021 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and AnalgesiaObjective: To evaluate the agreement between oscillometric blood pressure (OBP) measured from the tongue and invasive blood pressure (IBP), and to compare OBPs measured from the tongue with OBPs measured from the pelvic limb and tail. Study design: Prospective experimental study. Animals: A total of eight adult Beagle dogs weighing 11.1 ± 1.2 kg. Methods: Animals were premedicated with intravenous (IV) acepromazine (0.005 mg kg–1). Anesthesia was induced with alfaxalone (3 mg kg–1) IV and maintained with isoflurane. The dorsal pedal artery was catheterized for IBP measurements. Systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressure were simultaneously measured from the tongue, pelvic limb and tail. Based on invasive SAP, hypertension (>140 mmHg), normotension (90–140 mmHg) and hypotension (<90 mmHg) were induced by controlling end-tidal isoflurane concentrations and/or dobutamine/dopamine administration. Agreement between paired IBP and OBP measurements was analyzed with reference standards for noninvasive blood pressure devices used in small animals and humans. Results: Regardless of cuff placement, the mean bias ± standard deviation between IBP and OBP met veterinary (≤10 ± 15 mmHg) and human (<5 ± 8 mmHg) standards for MAP and DAP. SAP measurements provided by the OBP device showed unacceptable agreement with IBP, and the bias between methods increased at higher blood pressures, regardless of cuff site. During hypotension, tongue OBP showed the largest percentage of absolute difference <10 mmHg in relation to IBP for SAP (90%), MAP (97%), and DAP (93%), compared with pelvic limb (60%, 97% and 82%, respectively) and tail OBP (54%, 92% and 77%, respectively). Conclusions and clinical relevance: The tongue is a clinically useful site for measuring OBP in anesthetized Beagle dogs, providing reliable estimates of MAP and DAP. The tongue could replace other cuff placement sites and may be a relatively suitable site for assessing hypotension.-
dc.language영어-
dc.publisherBlackwell Publishing Inc.-
dc.titleEvaluation of the tongue for oscillometric measurement of arterial pressure in anesthetized Beagle dogs-
dc.typeArticle-
dc.identifier.doi10.1016/j.vaa.2021.11.003-
dc.citation.journaltitleVeterinary Anaesthesia and Analgesia-
dc.identifier.wosid000788810700001-
dc.identifier.scopusid2-s2.0-85122462741-
dc.citation.endpage155-
dc.citation.number2-
dc.citation.startpage149-
dc.citation.volume49-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorLee, Inhyung-
dc.contributor.affiliatedAuthorSon, Won-gyun-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusBLOOD-PRESSURE-
dc.subject.keywordPlusMONITOR-
dc.subject.keywordPlusAGREEMENT-
dc.subject.keywordPlusCUFF-
dc.subject.keywordPlusHYPERTENSION-
dc.subject.keywordAuthoragreement-
dc.subject.keywordAuthorcanine-
dc.subject.keywordAuthornoninvasive blood pressure-
dc.subject.keywordAuthorpelvic limb-
dc.subject.keywordAuthortail-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Veterinary Medicine
  • Department of Veterinary Medicine
Research Area Pain Medicine, Systematic Anesthesia, Veterinary Anesthesiology, 수의마취통증의학

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share