Publications

Detailed Information

A novel balloon technique to induce intra-abdominal hypertension and its effects on cardiovascular parameters in a conscious dog model

Cited 6 time in Web of Science Cited 6 time in Scopus
Authors

Jang, Min; Son, Won-gyun; Jo, Sang-min; Kim, Hyunseok; Shin, Chi Won; Lee, Inhyung

Issue Date
2018-07
Publisher
Blackwell Publishing Inc.
Citation
Journal of Veterinary Emergency and Critical Care, Vol.28 No.4, pp.326-333
Abstract
ObjectiveTo evaluate a new balloon technique to induce intra-abdominal hypertension (IAH) and abdominal compartment syndrome in a conscious dog model, and to evaluate the effect of intra-abdominal pressure (IAP) on cardiovascular, respiratory, and arterial blood gas values in conscious dogs with IAH. DesignProspective, experimental study. SettingUniversity-based small animal research facility. AnimalsSix healthy Beagle dogs, 4 males, and 2 females. InterventionsA new balloon device designed for this study using a Foley urethral catheter and latex balloon was placed in the abdominal cavity. Consecutive measurements of IAP were made by measuring the intravesicular pressure. The abdomen was inflated with air to IAPs of 10, 15, 20, and 25mmHg. Heart rate, respiratory rate, systolic arterial blood pressure, and arterial blood gases were evaluated at baseline and at 15, 30, 45, 60, 120, 240, and 300 minutes after IAP increase. Measurements and Main ResultsThe air insufflated into the intra-abdominal balloon device significantly increased the IAP and led to sustained IAH. The respiratory rate increased significantly (P < 0.05) when IAP was increased to 15, 20, and 25mmHg. Although heart rate, systolic arterial blood pressure, PaO2, and PaCO2 did not show statistically significant differences between baseline and posttreatment values over time, the dogs with increased IAP showed a distended abdomen and apparent discomfort, and 4/6 (67%) vomited. After measurement of IAP, air was removed. There were no adverse effects noted after removal of the balloon device. ConclusionThe balloon device was successfully insufflated and led to sustained IAH in conscious dogs. This balloon technique does not require general anesthesia for instillation or removal of gas after installment. An acute IAP increase in normal conscious dogs induced discomfort, vomiting, and increased respiratory effort.
ISSN
1479-3261
URI
https://hdl.handle.net/10371/201098
DOI
https://doi.org/10.1111/vec.12730
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Veterinary Medicine
  • Department of Veterinary Medicine
Research Area Pain Medicine, Systematic Anesthesia, Veterinary Anesthesiology, 수의마취통증의학

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share