Publications

Detailed Information

Evaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.

DC Field Value Language
dc.contributor.authorShin, Joo Young-
dc.contributor.authorChoi, Jin Seok-
dc.contributor.authorOh, Joo Youn-
dc.contributor.authorKim, Mee Kum-
dc.contributor.authorLee, Jin Hak-
dc.contributor.authorWee, Won Ryang-
dc.date.accessioned2024-05-16T01:54:15Z-
dc.date.available2024-05-16T01:54:15Z-
dc.date.created2023-04-26-
dc.date.created2023-04-26-
dc.date.created2023-04-26-
dc.date.issued2010-01-
dc.identifier.citationKorean Journal of Ophthalmology, Vol.24 No.3, pp.139-142-
dc.identifier.issn1011-8942-
dc.identifier.urihttps://hdl.handle.net/10371/202972-
dc.description.abstractPURPOSE: To evaluate corneal biomechanical properties in eyes that had previously undergone penetrating keratoplasty (PK) using the ocular response analyzer (ORA). METHODS: We recruited 26 patients who had received unilateral PK. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and cornea-compensated intraocular pressure (IOPcc) were measured with the ORA and were compared to the measurements from the contralateral eyes that did not undergo PK. RESULTS: The CH was 8.95+/-2.59 mmHg in eyes that underwent PK and 9.78+/-1.45 mmHg in the contralateral eyes that did not undergo PK (p=0.077). The CRF was 10.26+/-2.64 mmHg in post-PK eyes and 9.75+/-1.45 mmHg in the contralateral eyes (p=0.509), and the CH-CRF was significantly smaller in post-PK eyes (-1.31+/-2.32 mmHg in post-PK eyes vs. 0.03+/-0.88 mmHg in fellow eyes, p=0.016). The IOPg and IOPcc were significantly higher in the PK group than they were in the control group. The IOPcc's were 20.81+/-7.81 mmHg and 16.27+/-2.49 mmHg in post-PK and control eyes, respectively (p=0.011); and the IOPg's were 19.22+/-7.34 mmHg and 15.07+/-3.03 mmHg in post-PK and control eyes, respectively (p=0.019). The IOPcc-g's were 1.59+/-2.81 mmHg and 1.21+/-1.30 mmHg in post-PK and control eyes, respectively (p=0.412), and the central corneal thickness (CCT)'s were 489.11+/-90.60 microm and 556.24+/-42.84 microm in post-PK and control eyes, respectively (p=0.068). CONCLUSIONS: Following PK, CH tended to decrease while CRF tended to increase, significantly decreasing CH-CRF. A significantly higher intraocular pressure and a thinner CCT following PK may have contributed to the observed changes in these corneal biomechanical parameters.-
dc.language영어-
dc.publisher대한안과학회-
dc.titleEvaluation of corneal biomechanical properties following penetrating keratoplasty using the ocular response analyzer.-
dc.typeArticle-
dc.identifier.doi10.3341/kjo.2010.24.3.139-
dc.citation.journaltitleKorean Journal of Ophthalmology-
dc.identifier.scopusid2-s2.0-77957299750-
dc.citation.endpage142-
dc.citation.number3-
dc.citation.startpage139-
dc.citation.volume24-
dc.identifier.kciidART001450237-
dc.description.isOpenAccessY-
dc.contributor.affiliatedAuthorOh, Joo Youn-
dc.contributor.affiliatedAuthorLee, Jin Hak-
dc.contributor.affiliatedAuthorWee, Won Ryang-
dc.type.docTypeArticle-
dc.description.journalClass1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area 각막 및 외안부 질환, 백내장

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.