Publications
Detailed Information
A survey of experience-based preference of Nickel- Titanium rotary files and incidence of fracture among general dentists
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이우철 | - |
dc.contributor.author | 송민주 | - |
dc.contributor.author | 김의성 | - |
dc.contributor.author | 이효진 | - |
dc.contributor.author | 김현철 | - |
dc.date.accessioned | 2024-05-29T01:29:51Z | - |
dc.date.available | 2024-05-29T01:29:51Z | - |
dc.date.created | 2022-06-27 | - |
dc.date.issued | 2012-11 | - |
dc.identifier.citation | Restorative Dentistry and Endodontics, Vol.37 No.4, pp.201-206 | - |
dc.identifier.issn | 2234-7658 | - |
dc.identifier.uri | https://hdl.handle.net/10371/203909 | - |
dc.description.abstract | Objectives: The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. Materials and Methods: A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operators experience or preferred technique and frequency of re-use or incidence of file fracture was assessed. Results: A total of 348dentists (51.7%) responded. The most frequently used NiTi instruments was ProFile (39.8%) followed by ProTaper. The most preferred preparation technique was crowndown (44.6%). 54.3% of the respondents re-used NiTi files more than 10 times. There was a significant correlation between experience with NiTi files and the number of reuses (p = 0.0025). 54.6% of the respondents estimated experiencing file separation less than 5 times per year. The frequency of separation was significantly correlated with the instrumentation technique (p = 0.0003). Conclusions: A large number of general dentists in Korea prefer to re-use NiTi rotary files. As their experience with NiTi files increased, the number of re-uses increased, while the frequency of breakage decreased. Operators who adopt the hybrid technique showed less tendency of separation even with the increased number of re-use. | - |
dc.language | 영어 | - |
dc.publisher | 대한치과보존학회 | - |
dc.title | A survey of experience-based preference of Nickel- Titanium rotary files and incidence of fracture among general dentists | - |
dc.type | Article | - |
dc.identifier.doi | 10.5395/rde.2012.37.4.201 | - |
dc.citation.journaltitle | Restorative Dentistry and Endodontics | - |
dc.citation.endpage | 206 | - |
dc.citation.number | 4 | - |
dc.citation.startpage | 201 | - |
dc.citation.volume | 37 | - |
dc.identifier.kciid | ART001712950 | - |
dc.description.isOpenAccess | N | - |
dc.contributor.affiliatedAuthor | 이우철 | - |
dc.description.journalClass | 2 | - |
dc.subject.keywordAuthor | Crown-down technique | - |
dc.subject.keywordAuthor | Fracture incidence | - |
dc.subject.keywordAuthor | Hybrid technique | - |
dc.subject.keywordAuthor | Nickel-titanium rotary file | - |
dc.subject.keywordAuthor | Preference | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.