Publications

Detailed Information

Effect of a macroscopic groove on bone response and implant stability

DC Field Value Language
dc.contributor.authorYoon, Hyung-In-
dc.contributor.authorYeo, In-Sung-
dc.contributor.authorYang, Jae-Ho-
dc.date.accessioned2024-05-29T01:32:08Z-
dc.date.available2024-05-29T01:32:08Z-
dc.date.created2020-05-06-
dc.date.issued2010-12-
dc.identifier.citationClinical Oral Implants Research, Vol.21 No.12, pp.1379-1385-
dc.identifier.issn0905-7161-
dc.identifier.urihttps://hdl.handle.net/10371/203951-
dc.description.abstractObjectives The aim of this study was to investigate the effect of a macroscopic groove on bone response and implant stability during the early stages of healing using a rabbit tibia model. Materials and methods Anodized titanium implants with (n=24) and without (n=24) macroscopic grooves were prepared. A total of 12 rabbits were used and each received four implants: six rabbits with implants with macroscopic grooves (test group) and six rabbits with implants without macroscopic groves (control group). Histomorphometry, resonance frequency, and removal torque value were evaluated 2 and 6 weeks post-implant-insertion. Results At 2 and 6 weeks, there was no significant difference between the two groups in the percentage of bone-to-implant contact (P > 0.05). At 6 weeks, the test group had significantly higher implant stability quotient values than the control group (P < 0.05). At 2 and 6 weeks, implants with grooves showed a significantly greater resistance to reverse torque than control implants (P < 0.05). Conclusion The groove on the oxidized titanium surface may increase both resistance to shear load and adhesion at the bone-implant interface. A geometric feature such as a macroscopic groove may facilitate osseointegration and increase implant stability in various clinical conditions. Further studies are required to confirm whether the improvement in implant stability will enhance treatment success in humans. To cite this article:Yoon H-I, Yeo I-S, Yang J-H. Effect of a macroscopic groove on bone response and implant stability.Clin. Oral Impl. Res. 21, 2010; 1379-1385.doi: 10.1111/j.1600-0501.2010.01960.x.-
dc.language영어-
dc.publisherBlackwell Publishing Inc.-
dc.titleEffect of a macroscopic groove on bone response and implant stability-
dc.typeArticle-
dc.identifier.doi10.1111/j.1600-0501.2010.01960.x-
dc.citation.journaltitleClinical Oral Implants Research-
dc.identifier.wosid000284120200010-
dc.identifier.scopusid2-s2.0-78349275769-
dc.citation.endpage1385-
dc.citation.number12-
dc.citation.startpage1379-
dc.citation.volume21-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorYoon, Hyung-In-
dc.contributor.affiliatedAuthorYeo, In-Sung-
dc.contributor.affiliatedAuthorYang, Jae-Ho-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusRESONANCE FREQUENCY-ANALYSIS-
dc.subject.keywordPlusTITANIUM IMPLANTS-
dc.subject.keywordPlusHISTOMORPHOMETRIC EVALUATION-
dc.subject.keywordPlusSURFACE TOPOGRAPHIES-
dc.subject.keywordPlusDENTAL IMPLANTS-
dc.subject.keywordPlusANIMAL-MODEL-
dc.subject.keywordPlusIN-VIVO-
dc.subject.keywordPlusOSSEOINTEGRATION-
dc.subject.keywordPlusTORQUE-
dc.subject.keywordPlusINTERFACE-
dc.subject.keywordAuthorbone-to-implant contact-
dc.subject.keywordAuthormacroscopic groove-
dc.subject.keywordAuthorrabbit tibia-
dc.subject.keywordAuthorremoval torque-
dc.subject.keywordAuthorresonance frequency-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share