Publications

Detailed Information

Measurement variability of persistent pulmonary subsolid nodules on same-day repeat CT: What is the threshold to determine true nodule growth during follow-up?

Cited 20 time in Web of Science Cited 22 time in Scopus
Authors

Kim, Hyungjin; Park, Chang Min; Song, Yong Sub; Sunwoo, Leonard; Choi, Ye Ra; Kim, Jung Im; Kim, Jae Hyun; Bae, Jae Seok; Lee, Jong Hyuk; Goo, Jin Mo

Issue Date
2016-02
Publisher
PUBLIC LIBRARY SCIENCE
Citation
PLOS ONE, Vol.11 No.2, p. e0148853
Abstract
Purpose To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics. Methods Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons. Results Measurement variability for the longest and average diameter of SSNs was +/- 1.3 mm (+/- 13.0%) and +/- 1.3 mm (+/- 14.4%) in situation 1, and +/- 2.2 mm (+/- 21.0%) and +/- 2.1 mm (+/- 21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was +/- 1.2 mm (+/- 27.1%) and +/- 0.8 mm (+/- 24.0%) in situation 1, and +/- 3.7 mm (+/- 61.0%) and +/- 1.5 mm (+/- 47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001). Conclusions A cutoff of +/- 2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs' change when readers of initial and follow-up CT were different.
ISSN
1932-6203
URI
https://hdl.handle.net/10371/207009
DOI
https://doi.org/10.1371/journal.pone.0148853
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Radiology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share