Publications

Detailed Information

Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction

Cited 43 time in Web of Science Cited 46 time in Scopus
Authors

Choo, Ji Yung; Goo, Jin Mo; Lee, Chang Hyun; Park, Chang Min; Park, Sang Joon; Shim, Mi-Suk

Issue Date
2014-04
Publisher
SPRINGER
Citation
EUROPEAN RADIOLOGY, Vol.24 No.4, pp.799-806
Abstract
To evaluate filtered back projection (FBP) and two iterative reconstruction (IR) algorithms and their effects on the quantitative analysis of lung parenchyma and airway measurements on computed tomography (CT) images. Low-dose chest CT obtained in 281 adult patients were reconstructed using three algorithms: FBP, adaptive statistical IR (ASIR) and model-based IR (MBIR). Measurements of each dataset were compared: total lung volume, emphysema index (EI), airway measurements of the lumen and wall area as well as average wall thickness. Accuracy of airway measurements of each algorithm was also evaluated using an airway phantom. EI using a threshold of -950 HU was significantly different among the three algorithms in decreasing order of FBP (2.30 %), ASIR (1.49 %) and MBIR (1.20 %) (P < 0.01). Wall thickness was also significantly different among the three algorithms with FBP (2.09 mm) demonstrating thicker walls than ASIR (2.00 mm) and MBIR (1.88 mm) (P < 0.01). Airway phantom analysis revealed that MBIR showed the most accurate value for airway measurements. The three algorithms presented different EIs and wall thicknesses, decreasing in the order of FBP, ASIR and MBIR. Thus, care should be taken in selecting the appropriate IR algorithm on quantitative analysis of the lung. aEuro cent Computed tomography is increasingly used to provide objective measurements of intra-thoracic structures. aEuro cent Iterative reconstruction algorithms can affect quantitative measurements of lung and airways. aEuro cent Care should be taken in selecting reconstruction algorithms in longitudinal analysis. aEuro cent Model-based iterative reconstruction seems to provide the most accurate airway measurements.
ISSN
0938-7994
URI
https://hdl.handle.net/10371/207457
DOI
https://doi.org/10.1007/s00330-013-3078-5
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Radiology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share