Publications
Detailed Information
Transient part-solid nodules detected at screening thin-section ct for lung cancer: Comparison with persistent part-solid nodules
Cited 102 time in
Web of Science
Cited 114 time in Scopus
- Authors
- Issue Date
- 2010
- Publisher
- Radiological Society of North America
- Citation
- Radiology, Vol.255 No.1, pp.242-251
- Abstract
- Purpose: To retrospectively investigate clinical and computed tomographic (CT) features of transient part-solid nodules (PSNs) initially detected at screening thin-section CT for lung cancer and to determine predictive factors that may differentiate transient PSNs from persistent PSNs. Materials and Methods: This study was approved by the institutional review board. From January 2006 to August 2008, 93 individuals with 126 PSNs were identified from among 16 777 individuals who underwent chest CT. Clinical features and CT characteristics of PSNs were reviewed, and clinical and thinsection CT features were compared between transient and persistent PSNs. To identify predictive factors of transient PSNs and evaluate predictive performance, logistic regression analysis and C statistic analysis were performed. Results: Eighty-eight (69.8%) of 126 PSNs were transient. Between transient and persistent PSNs, there were significant differences (P <.05) in patient age, patient sex, risk of lung cancer, presence of eosinophilia, mode of detection, lesion size, lesion multiplicity, size of solid portion, and lesion border. Multivariate analysis revealed that young patient age, detection of the lesion at follow-up, blood eosinophilia, lesion multiplicity, large solid portion, and ill-defined border were significant (P <.05) independent predictors of transient PSNs. The performance in the discrimination of transient PSNs from persistent PSNs of the logistic regression model that incorporated both clinical and thin-section CT features was significantly higher than the performance of the models that incorporated clinical features or thinsection CT features alone. Conclusion: A s ubstantial proportion of PSNs detected at screening CT were transient. Transient PSNs could be predicted with high accuracy by using the features of young patient age, detection of the PSN at follow-up, blood eosinophilia, lesion multiplicity, large solid portion, and ill-defined lesion border. © RSNA, 2010.
- ISSN
- 0033-8419
- Files in This Item:
- There are no files associated with this item.
- Appears in Collections:
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.