Publications

Detailed Information

Micrometer resolution imaging using unmonochromatized synchrotron x-rays: Phantom, human breast tissue, and live animal imaging studies

DC Field Value Language
dc.contributor.authorKim, Hee Joung-
dc.contributor.authorJung, Ha Jjo-
dc.contributor.authorHong, Jin O.-
dc.contributor.authorJeong, Ha Kyu-
dc.contributor.authorKim, Eun Kyung-
dc.contributor.authorLee, Kyu Ho-
dc.contributor.authorSeong, Je Kyung-
dc.contributor.authorJe, Jung Ho-
dc.contributor.authorKim, IW-
dc.contributor.authorHwu, Yeu Kuang-
dc.contributor.authorTsai, Wen Li-
dc.contributor.authorYoo, Hyung Sik-
dc.date.accessioned2024-08-08T01:51:45Z-
dc.date.available2024-08-08T01:51:45Z-
dc.date.created2024-08-05-
dc.date.created2024-08-05-
dc.date.issued2001-06-
dc.identifier.citationProceedings of SPIE - The International Society for Optical Engineering, Vol.4320, pp.409-416-
dc.identifier.issn0277-786X-
dc.identifier.urihttps://hdl.handle.net/10371/208767-
dc.description.abstractA new 5C1 beam line was recently built on Pohang Light Source (PLS) in Korea for possible medical applications. An imaging system on the beam line consisted of silicon wafer attenuators, tungsten slit, CdWO4 scintillator, CCD camera, and personal computer. Both spatial resolution test pattern and glass capillary filled with air bubbles were imaged to evaluate resolution and phase-contrast effects for synchrotron imaging system, respectively. Mammographic accreditation phantom, cancerous human breast specimens, and fish and nude mouse were also imaged. Both spatial resolution and image quality of the synchrotron imaging system were compared with those of conventional mammography system. The images of resolution test pattern showed a few tens of micrometer spatial resolution on synchrotron imaging system. The images of capillary filled with air bubbles revealed phase contrast effect. Mammographic accreditation phantom, human breast specimen, and animal images with synchrotron imaging system showed much higher resolution with great details of object and higher enhanced contrast compared to those with conventional mammography system. We successfully implemented and tested a micrometer resolution imaging system on PLS 5C1 beam line. Using a simple and inexpensive synchrotron imaging system on PLS 5C1 beam line, micrometer resolution images for resolution test pattern, mammographic accreditation phantom, human breast specimens, and Eve animals were acquired and visually evaluated.-
dc.language영어-
dc.publisherSPIE-
dc.titleMicrometer resolution imaging using unmonochromatized synchrotron x-rays: Phantom, human breast tissue, and live animal imaging studies-
dc.typeArticle-
dc.identifier.doi10.1117/12.430898-
dc.citation.journaltitleProceedings of SPIE - The International Society for Optical Engineering-
dc.identifier.wosid000171047400045-
dc.identifier.scopusid2-s2.0-17944382468-
dc.citation.endpage416-
dc.citation.startpage409-
dc.citation.volume4320-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorSeong, Je Kyung-
dc.type.docTypeProceedings Paper-
dc.description.journalClass1-
dc.subject.keywordPlusREFRACTION-
dc.subject.keywordPlusRADIATION-
dc.subject.keywordAuthorsynchrotron radiation-
dc.subject.keywordAuthorunmonochromatized x-rays-
dc.subject.keywordAuthorphase contrast-
dc.subject.keywordAuthorreal-time imaging-
dc.subject.keywordAuthorscintillator plate-
dc.subject.keywordAuthorCCD camera-
dc.subject.keywordAuthorspatial resolution pattern-
dc.subject.keywordAuthormammographic accreditation phantom-
dc.subject.keywordAuthorhuman breast specimen-
dc.subject.keywordAuthorPLS-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Veterinary Medicine
  • Department of Veterinary Medicine
Research Area Metabolic syndrome model construction and omics research, Mouse locomotion and metabolic phenotyping analysis, Study of immune regulatory response in obesity, 대사증후군 모델 구축 및 오믹스 연구, 마우스 운동 및 대사 표현형 분석, 비만에서의 면역 조절 반응 연구

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share