Publications

Detailed Information

Accuracy and complications of percutaneous transthoracic needle lung biopsy for the diagnosis of malignancy in patients with idiopathic pulmonary fibrosis

Cited 19 time in Web of Science Cited 24 time in Scopus
Authors

Shin, Yoon Joo; Yun, Gabin; Yoon, Sung Hyun; Song, Hwayoung; Kim, Junghoon; Kim, Jihang; Park, Jong Sun; Lee, Kyoung Won; Lee, Kyung Hee

Issue Date
2021-12
Publisher
Springer Verlag
Citation
European Radiology, Vol.31 No.12, pp.9000-9011
Abstract
Objectives To determine the accuracy of CT-guided percutaneous transthoracic needle lung biopsy (PTNB) for the diagnosis of malignancy and the associated complication rates in patients with idiopathic pulmonary fibrosis (IPF). Methods This retrospective study included 91 CT-guided PTNBs performed in 80 patients with IPF from April 2003 through December 2016. Data regarding patients, target lesions, procedures, complications, and pathological reports were collected, and the final diagnosis was made. The diagnostic accuracy, sensitivity, specificity, percentage of nondiagnostic results, and complication rates were determined. Multivariable logistic regression analyses were performed to identify risk factors for nondiagnostic results and major complications. Results Three biopsies (technical failure [n = 2] and undetermined final diagnosis [n = 1]) were excluded from the diagnostic accuracy calculation. The diagnostic accuracy, sensitivity, and specificity were 89% (78/88), 90% (62/69), and 84% (16/19), respectively. The percentage of nondiagnostic results was 34% (30/88). Lesion size <= 3 cm (odds ratio [OR], 8.8; 95% confidence interval [CI], 2.5-31.2; p = 0.001) and needle tip placement outside the target lesion (OR, 13.7; 95% CI, 1.4-132.2; p = 0.02) were risk factors for nondiagnostic results. The overall and major complication rates were 51% (46/91) and 12% (11/91), respectively. The presence of honeycombing along the path of the needle (OR, 11.2; 95% CI, 1.4-89.1; p = 0.02) was an independent risk factor for major complications. Conclusions CT-guided PTNB shows a relatively reasonable accuracy in diagnosing malignancy in patients with IPF. The complication rate may be high, especially when the needle passes through honeycomb lesions.
ISSN
0938-7994
URI
https://hdl.handle.net/10371/216998
DOI
https://doi.org/10.1007/s00330-021-08038-x
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Interstitial lung disease, Pneumonia, Pulmonary fibrosis, 간질성 폐질환, 폐렴, 폐섬유증

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share