Long-term results of the Cox-Maze III procedure for persistent atrial fibrillation associated with rheumatic mitral valve disease: 10-year experience
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Kwan Chang | - |
dc.contributor.author | Cho, Kwang Ree | - |
dc.contributor.author | Kim, Yong-Jin | - |
dc.contributor.author | Sohn, Dae-Won | - |
dc.contributor.author | Kim, Ki-Bong | - |
dc.date.accessioned | 2010-01-08T05:23:03Z | - |
dc.date.available | 2010-01-08T05:23:03Z | - |
dc.date.issued | 2006-12-13 | - |
dc.identifier.citation | Eur J Cardiothorac Surg. 2007 Feb;31(2):261-6. Epub 2006 Dec 8. | en |
dc.identifier.issn | 1010-7940 (Print) | - |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17158057 | - |
dc.identifier.uri | https://hdl.handle.net/10371/28907 | - |
dc.description.abstract | OBJECTIVE: We evaluated the long-term results of the Cox-Maze III procedure (CM-III) for persistent atrial fibrillation (AF) associated with rheumatic mitral valve (MV) disease. METHODS: We analyzed 127 patients who underwent the CM-III combined with a rheumatic MV procedure between 1994 and 2004. In-hospital mortalities were excluded from the study. RESULTS: There were 10 late deaths and the mean follow-up duration was 7.1+/-2.8 years (range, 13 months to 11.5 years). Normal sinus rhythm was restored in 88.2% (112/127) after the CM-III. Right atrial contractility was demonstrable in 100% (112/112) and left atrial contractility in 68.8% (77/112) of the patients restored to sinus rhythm. Fifteen patients never regained sinus rhythm after the CM-III (AF treatment failure). Permanent pacemakers were implanted in 4.7% (6/127) of the patients during the follow-up. Late recurrence of AF developed in 34 of 112 patients at 44+/-27 months postoperatively, and sinus rhythm was restored in 29 of 34 patients by administration of an antiarrhythmic medication. Independent risk factors for late AF recurrence were longer duration of AF (>60 months) (odds ratio (OR)=2.758, p=0.025), increased left atrial size (OR=1.113, p=0.004). Freedom from AF recurrence was 93% at 1-year, 82% at 3 years, 71% at 5 years, and 63% at 7 years. Risk factors for AF treatment failure were longer duration of AF (>60 months) (p<0.001) and increased patient age (p=0.030). A higher prevalence of significant late tricuspid regurgitation was observed in patients with AF treatment failure and those with late AF recurrence. CONCLUSIONS: The CM-III for persistent AF associated with rheumatic MV disease demonstrated a progressively decreased cure rate during the follow-up period. Early surgical therapy, aggressive left atrial reduction, and correction of tricuspid regurgitation at the time of surgery may increase the long-term success rate. | en |
dc.language.iso | en | en |
dc.publisher | Elsevier | en |
dc.subject | Adult | en |
dc.subject | Aged | en |
dc.subject | Atrial Fibrillation/etiology/*surgery | en |
dc.subject | Epidemiologic Methods | en |
dc.subject | Female | en |
dc.subject | Heart Atria/pathology | en |
dc.subject | Heart Valve Diseases/*complications | en |
dc.subject | Humans | en |
dc.subject | Male | en |
dc.subject | Middle Aged | en |
dc.subject | Recurrence | en |
dc.subject | Rheumatic Heart Disease/*complications | en |
dc.subject | Treatment Failure | en |
dc.subject | Treatment Outcome | en |
dc.subject | Tricuspid Valve Insufficiency/complications | en |
dc.subject | Mitral Valve | - |
dc.title | Long-term results of the Cox-Maze III procedure for persistent atrial fibrillation associated with rheumatic mitral valve disease: 10-year experience | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 김관창 | - |
dc.contributor.AlternativeAuthor | 조광리 | - |
dc.contributor.AlternativeAuthor | 김용진 | - |
dc.contributor.AlternativeAuthor | 손대원 | - |
dc.contributor.AlternativeAuthor | 김기봉 | - |
dc.identifier.doi | 10.1016/j.ejcts.2006.11.017 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.