Publications

Detailed Information

The efficacy of an acrylic intraocular lens surface modified with polyethylene glycol in posterior capsular opacification

DC Field Value Language
dc.contributor.authorLee, Hyeon Il-
dc.contributor.authorKim, Mee Kum-
dc.contributor.authorKo, Jung Hwa-
dc.contributor.authorLee, Hyun Ju-
dc.contributor.authorWee, Won Ryang-
dc.contributor.authorLee, Jin Hak-
dc.date.accessioned2010-01-08T08:34:06Z-
dc.date.available2010-01-08T08:34:06Z-
dc.date.issued2007-06-29-
dc.identifier.citationJ Korean Med Sci. 2007 Jun;22(3):502-7.en
dc.identifier.issn1011-8934 (Print)-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=17596661-
dc.identifier.urihttps://hdl.handle.net/10371/29084-
dc.description.abstractTo investigate if the surface modification of intraocular lens (IOL) is efficient in the prevention of posterior capsular opacification (PCO), the acrylic surface of intraocular lens (Acrysof) was polymerized with polyethylene glycol (PEG-IOL). The human lens epithelial cells (1 x 10(4) cells/mL) were inoculated on PEG grafted or unmodified acrylic lenses for the control. The adherent cells on each IOL surface were trypsinized and counted. The every PEG-IOL was implanted in 20 New Zealand rabbits after removal of crystalline lens. The formations of PCO were checked serially through retroilluminated digital photography, and the severity scores were calculated using POCOman. The cell adherence patterns on each IOL were examined by scanning electron microscopy. As a result, the mean number of adherent cells of PEG-IOL (3.2+/-1.1 x 10(3)) tended to be smaller than that of the acrylic controls (3.6+/-1.9 x 10(3)) without a statistical significance (p=0.73). However, the mean severity of PCO formation in PEG-IOL was significantly lower than that in the control during the third to sixth weeks after surgery. Scanning electron microscopy revealed that the more patch-like cells were found firmly attached to the IOL surface in control than in the PEG-IOL. Conclusively, PEG polymerization to the acrylic IOL would possibly lessen the formation of PCO after cataract removal.en
dc.language.isoenen
dc.publisherKorean Academy of Medical Scienceen
dc.subjectAcrylic Resins/chemistryen
dc.subjectBiocompatible Materialsen
dc.subjectCataract/metabolism/*therapyen
dc.subjectCell Adhesionen
dc.subjectHumansen
dc.subjectLens Implantation, Intraocular/*methodsen
dc.subjectLens, Crystalline/cytology/ultrastructureen
dc.subjectMicroscopy, Electron, Scanningen
dc.subjectPolyethylene Glycols/*chemistry/metabolismen
dc.subjectTime Factorsen
dc.titleThe efficacy of an acrylic intraocular lens surface modified with polyethylene glycol in posterior capsular opacificationen
dc.typeArticleen
dc.contributor.AlternativeAuthor이현일-
dc.contributor.AlternativeAuthor김미금-
dc.contributor.AlternativeAuthor고정화-
dc.contributor.AlternativeAuthor이현주-
dc.contributor.AlternativeAuthor위원량-
dc.contributor.AlternativeAuthor이진학-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share