Publications

Detailed Information

임플란트 생체금속들과 골조직간의 생체적합도에 관한 연구 : BICOMPATIBILITY OF BICOMTALS IN RABBIT BONE

DC Field Value Language
dc.contributor.author한종현-
dc.contributor.author허성주-
dc.contributor.author정종평-
dc.contributor.author구영-
dc.contributor.author류인철-
dc.contributor.author최용창-
dc.date.accessioned2010-01-19T04:14:41Z-
dc.date.available2010-01-19T04:14:41Z-
dc.date.issued1997-
dc.identifier.citation대한치과보철학회지, 35(3) : 557-565en
dc.identifier.issn0301-2875-
dc.identifier.urihttps://hdl.handle.net/10371/37642-
dc.description.abstractScrew-shaped implants of commercially pure (c.p.) titanium, c.p. niobium, c.p. zirconium, and stainless steel(Sus 304) were inserted in the rabbit tibial bone over 12 weeks of follow-up. New developed torque gauge instrument was used to evaluate the implant holding power and a image analysis program coupled to a microscope was used for histomorphometry. The three best consecutive threads of each implant were measured. Quantitative analyses at 12 weeks revealed a partial bone contact to the four kinds investigated metals. There were no obvious adverse tissue reactions to any of the biomaterials. At 12 weeks the average removal torques for titanium, niobium and zirconium were better than that needed for Sus 304 screws, on the other hand high score of bony contact ratio of titanium and niobium were showed in comparison to those of zirconium and Sus 304. There was no significant differences in the amount of interfacial bone of zirconium and Sus 304 whereas there was significant difference in the torque forces of niobium and Sus 304. Three months after implant insertion, the average removal torque was 6.64 Ncm for the titanium, 6.57 Ncm for the niobium, 6.38 Ncm for the zirconium, and 4.25 Ncm for the Sus 304. On average bone contacts there were 51.24% in the titanium, 48.19% in the niobium, 31.79% in the zirconium, 23.54% in the Sus 304. Biocompatibility of the titanium, niobium and zirconium was acceptable level in comparison to the Sus 304.en
dc.description.sponsorship본 연구는 보건복지부 1995년도 G-7 연구비(HMP-95-G-2-28) 지원에 의해 이루어졌음.en
dc.language.isokoen
dc.publisher대한치과보철학회en
dc.subject골유착성임플란트en
dc.subject골접촉률en
dc.subject뒤틀림제거력en
dc.subject비탈회표본en
dc.subject생체금속en
dc.subject생체적합도en
dc.title임플란트 생체금속들과 골조직간의 생체적합도에 관한 연구en
dc.title.alternativeBICOMPATIBILITY OF BICOMTALS IN RABBIT BONEen
dc.typeArticleen
dc.contributor.AlternativeAuthorHan, Chong-Hyun-
dc.contributor.AlternativeAuthorHoe, Seong-Joo-
dc.contributor.AlternativeAuthorChung, Chong-Pyong-
dc.contributor.AlternativeAuthorKu, Young-
dc.contributor.AlternativeAuthorRhyu, In-Chul-
dc.contributor.AlternativeAuthorChoi, Yong-Chang-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share