Publications

Detailed Information

공초점 레이저 주사 현미경을 이용한 실험적 레진의 표면 조도에 대한 연구 : SURFACE ROUGHNESS OF EXPERIMENTAL COMPOSITE RESINS USING CONFOCAL LASER SCANNING MICROSCOPE

DC Field Value Language
dc.date.accessioned2010-02-01T06:06:44Z-
dc.date.available2010-02-01T06:06:44Z-
dc.date.issued2008-
dc.identifier.citation33:1, 2008en
dc.identifier.issn1225-0864-
dc.identifier.urihttps://hdl.handle.net/10371/47329-
dc.description.abstractThe purpose of this study was to evaluate the effect of a new resin monomer, filler size and polishing technique on the surface roughness of composite resin restorations using confocal laser scanning microscopy. By adding new methoxylated Bis-GMA (Bis-M-GMA, 2,2-bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane) having low viscosity, the content of TEGDMA might be decreased. Three experimental composite resins were made: EX1 (Bis-M-GMA/TEGDMA = 95/5 wt%, 40 nm nanofillers); EX2 (Bis-M-GMA/TEGDMA = 95/5 wt%, 20 nm nanofillers); EX3 (Bis-GMA/TEGDMA = 70/30 wt%, 40 nm nanofillers). Filtek Z250 was used as a reference. Nine specimens (6 mm in diameter and 2 mm in thickness) for each experimental composite resin and Filtek Z250 were fabricated in a teflon mold and assigned to three groups. In Mylar strip group, specimens were left undisturbed. In Sof-lex group, specimens were ground with #1000 SiC paper and polished with Sof-lex discs. In DiaPolisher group, specimens were ground with #1000 SiC paper and polished with DiaPolisher polishing points. The Ra (Average roughness), Rq (Root mean square roughness), Rv (Valley roughness), Rp (Peak roughness), Rc (2D roughness) and Sc (3D roughness) values were determined using confocal laser scanning microscopy. The data were statistically analyzed by Two-way ANOVA and Tukey multiple comparisons test (p = 0.05). The type of composite resin and polishing technique significantly affected the surface roughness of the composite resin restorations (p < 0.001). EX3 showed the smoothest surface compared to the other composite resins (p < 0.05). Mylar strip resulted in smoother surface than other polishing techniques (p < 0.05). Bis-M-GMA. a new resin monomer having low viscosity, might reduce the amount of diluent, but showed adverse effect on the surface roughness of composite resin restorations.en
dc.language.isokoen
dc.publisher대한치과보존학회en
dc.subjectBis-M-GMAen
dc.subjectconfocal laser scanning microscopyen
dc.subjectfiller sizeen
dc.subjectnew resin monomeren
dc.subjectsurface roughnessen
dc.title공초점 레이저 주사 현미경을 이용한 실험적 레진의 표면 조도에 대한 연구en
dc.title.alternativeSURFACE ROUGHNESS OF EXPERIMENTAL COMPOSITE RESINS USING CONFOCAL LASER SCANNING MICROSCOPEen
dc.typeArticleen
dc.contributor.AlternativeAuthor배지현-
dc.contributor.AlternativeAuthor이미애-
dc.contributor.AlternativeAuthor조병훈-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share