Publications

Detailed Information

수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구

DC Field Value Language
dc.contributor.author손병섭-
dc.contributor.author장익태-
dc.contributor.author허성주-
dc.contributor.author곽재영-
dc.date.accessioned2010-02-01T09:40:28Z-
dc.date.available2010-02-01T09:40:28Z-
dc.date.issued2001-
dc.identifier.citation대한치과보철학회지 39(4): 336-350, 2001en
dc.identifier.issn0301-2875-
dc.identifier.urihttp://uci.or.kr/G100:I100-KOI(KISTI1.1003/JNL.JAKO200126813003696)-
dc.identifier.urihttps://hdl.handle.net/10371/47577-
dc.description.abstractThe purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic() and scanning electron microscopic view(SEM ) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.en
dc.language.isokoen
dc.publisher대한치과보철학회en
dc.subjectDental magnetic attachmenten
dc.subjectCorrosion resistanceen
dc.subjectPotentiodynamic polarization techniqueen
dc.subjectPitting corrosionen
dc.title수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구en
dc.typeArticleen
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share