Publications

Detailed Information

산화 티타늄 블라스팅 임프란트 표면구조에 대한 염산 테트라싸이클린의 영향 : Micromorphometric change of TiO₂blast implant surface conditioned with tetracycline-HCI

DC Field Value Language
dc.contributor.author이정민-
dc.contributor.author허익-
dc.contributor.author권영혁-
dc.contributor.author박준봉-
dc.contributor.author정종혁-
dc.contributor.author허성주-
dc.date.accessioned2010-02-01T09:47:30Z-
dc.date.available2010-02-01T09:47:30Z-
dc.date.issued2007-
dc.identifier.citation대한치주과학회지 2007;37:599-611.en
dc.identifier.issn0250-3352-
dc.identifier.urihttps://hdl.handle.net/10371/47720-
dc.description.abstractThe present study was performed to evaluate the surface roughness and effect of Tetracycline-HCI on the change of implant surface microstructure according to application time. TiO₂ surface Implant was utilized. Implant surface was rubbed with 50mg/ml Tetracycline-HCI solution for 0.5min, 1min, 1.5min, 2min, 2.5min and 3min respectively in the Tetracycline-HCI group. Then, specimens were measured surface roughness and processed for scanning electron microscopic observation. The results of this study were as follows. 1. TiO₂ blast implant surface showed increased surface roughness 1.5 minute after treatment with Tetracycline-HCI. But, there were not significant differences in saline group after treatment. 2. Tetracycline-HCI group showed changed surface micro-morphology in SEM after 1.5 minute. There were not significant differences in saline group after treatment. 3. Between Tetracycline-HCI group and saline group, there were difference in surface roughness change and SEM micro-morphology. Tetracycline-HCI have influence on TiO₂ blast implant surface. In conclusion, the detoxification with 50mg/ml Tetracycline-HCI must be applied respectively with different time according to various implant surfaces.en
dc.language.isokoen
dc.publisher대한치주과학회en
dc.subjectTiO₂en
dc.subjectblast implant surfaceen
dc.subjecttetracyclina-HCIen
dc.subjectdetoxificationen
dc.title산화 티타늄 블라스팅 임프란트 표면구조에 대한 염산 테트라싸이클린의 영향en
dc.title.alternativeMicromorphometric change of TiO₂blast implant surface conditioned with tetracycline-HCIen
dc.typeArticleen
dc.contributor.AlternativeAuthorLee, Jung-Min-
dc.contributor.AlternativeAuthorHerr, Yeek-
dc.contributor.AlternativeAuthorKwon, Young-Hyuk-
dc.contributor.AlternativeAuthorPark, Joon-Bong-
dc.contributor.AlternativeAuthorChung, Jong-Hyuk-
dc.contributor.AlternativeAuthorHeo, Seong-Joo-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share