Browse
S-Space
College of Dentistry/School of Dentistry (치과대학/치의학대학원)
Dept. of Dentistry (치의학과)
Journal Papers (저널논문_치의학과)
Cemented type implant에서 지대치의 표면조도와 cement의 종류가 Retrievability에 미치는 영향에 관한 연구 : THE RETRIEVABILITY OF CEMENTATION TYPE IMPLANT ABUTMENT BY SURFACE TREATEMENTS AND TYPES OF CEMENTS
- Authors
- Issue Date
- 1999
- Publisher
- 대한치과보철학회
- Citation
- 37(5); 1999
- Abstract
- This study was performed to investigate the retrievability of the cementation type implant abutments. The cements used in this study were Cavitec, Tembond and Zinc Phosphate Cement. The types of surface conditioning were no treatment, 50 microne sandblasting, 250 microne sandblasting, fine diamond finishing point and coarse diamond point. The retention of cast crown was measured with Instron Universal Testing Machine(Instron Engineering Co., U.S.A.). The results were as fellows: 1. The Maximium retention was obtained by the group of Z.P.C. cementation and Coarse diamond point surface conditioning. 2. Z.P.C. shows maximum retention, and reduced in orders Tembond, Cavitec, No cement. 3. The value of retention of surface condition was highest in coarse diamond point, lowest in no tretment. 4. The similar results were obtained between fine diamond point and 50 microne sandblasting, coarse diamond point and 250 microne sandblasting. 5. The were no direct corelation between mechanical retention and cementation retention.
- ISSN
- 0301-2875
- Language
- English