Publications

Detailed Information

중합시간과 중합방법에 따른 자가중합형 상교정용 레진의 중합률의 비교에 관한 연구

DC Field Value Language
dc.contributor.author유종욱-
dc.contributor.author장기택-
dc.contributor.author김종철-
dc.date.accessioned2010-02-01T09:52:25Z-
dc.date.available2010-02-01T09:52:25Z-
dc.date.issued1999-
dc.identifier.citation대한소아치과학회지 26:296-309, 1999.en
dc.identifier.issn1226-8496-
dc.identifier.urihttps://hdl.handle.net/10371/47818-
dc.description.abstractAutopolymerized resin facilitates a more rapid and easier means for the construction of removable orthodontic appliances than heat cured resin. But many reports reveal that more unreacted monomer is found in autopolymerized resin. It is very important to achieve maximum degree of polymerization because if polymerization is inadequate, high level of unreacted monomer has been shown to adversely affect mechanical and physical properties, and also the question of allergy or toxicity to methylmethacrylate must be considered. The purpose of this study was to compare the degree of polymerization according to curing method and curing time. Five groups were desinged ; Group 1 was polymerizied at room temperature() ; Group 2 in water ; Group 3 in water under 30psi pressure ; Group 4 in water ; Group 5 in water under 30psi pressure for 10 minutes, 1 hour 12 hours, 1 day and 3 days. The degree of polymerization was measured by means of Fourier Transform Infrared spectroscopy. The results were as follows: 1. The degree of polymerization increased constantly in accordance with curing time in all groups and after curing for 10 minutes, Group 1 showed significantly higher degree of polymerization after 12 hours and Group 2, Group 3, Group 4, Group 5 after 1 hour(p<0.05). 2. The degree of polymerization decreased in the order of Group 5, Group 4, Group 3, Group 2, Group 1 except when the curing time was 1 hour and 12 hours(p<0.05). 3. The degree of polymerization of Group 4, Group 5 cured at showed significantly higher degree of polymerization than Group 2, Group 3 at except when the curing time was 1 day(p<0.05). 4. Among Group 2, Group 3 and Group 4, Group 5, the pressure had no effect on polymerization except when the curing time was 12 hours(p<0.05). 5. Between Group 1 and Group 2, the method of storage had no effect on polymerization except when the curing time was 1 hour(p<0.05).en
dc.language.isokoen
dc.publisher대한소아치과학회en
dc.subjectautopolymerized resinen
dc.subjectFourier Transform Infared spectroscopyen
dc.subjectheat cured resinen
dc.subjectpolymerizationen
dc.subjectunreacted monomeren
dc.title중합시간과 중합방법에 따른 자가중합형 상교정용 레진의 중합률의 비교에 관한 연구en
dc.typeArticleen
dc.contributor.AlternativeAuthorYoo, Jong-Wook-
dc.contributor.AlternativeAuthorJang, Ki-Taeg-
dc.contributor.AlternativeAuthorKim, Chong-Chul-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share