Publications

Detailed Information

DLC표면 처리에 따른 임플랜트 지대주 나사의 풀림 현상에 관한 연구

DC Field Value Language
dc.contributor.author곽재영-
dc.contributor.author허성주-
dc.contributor.author장익태-
dc.contributor.author임순호-
dc.contributor.author이종엽-
dc.contributor.author이광렬-
dc.date.accessioned2010-02-01T09:53:45Z-
dc.date.available2010-02-01T09:53:45Z-
dc.date.issued2003-
dc.identifier.citation대한치과보철학회지 2003;41:128-135.en
dc.identifier.issn0301-2875-
dc.identifier.urihttp://uci.or.kr/G100:I100-KOI(KISTI1.1003/JNL.JAKO200326812997171)-
dc.identifier.urihttps://hdl.handle.net/10371/47845-
dc.description.abstractStatement of problem : Implant screw loosening remains a problem in implant prosthodontics. Some abutment screws with treated surfaces were introduced to prevent screw loosening and to increase preload. DLC(Diamond Like Carbon) film has similar properties on hardness, wear resistance, chemical stability, biocompatibility as real diamond materials. Purpose : The purpose of this study was to investigate the effect of lubricant layer on abutment screw and to discriminate more effective method between soft lubricant and hard lubricant to prevent screw loosening. Material and method : In this study, thickness DLC was used as protective, lubricating layer of titanium screws and 3 times removal torque was measured on the abutment screws to investigate the difference in 10 coated and 10 non-coated abutment screws. Results : The results indicated that the implants with DLC coating group were not more resistant to the applied force in screw loosening. At 32Ncm, the 3 times removal torque in DLC group were 27.75+-2.89, 25.85+-2.35 and 26.2+-2.57 . The removal torque in no-coated abutment screws were 27.85+_4.23, 27.35+-2.81 and 27.9+_2.31 , respectively. Conclusion : The lubricant layer used in this study was Diamond Like Carbon(DLC) and it have a properties of hard and stable layer. The DLC coating layer was hard enough to prevent distortion of screws in the repeated unscrewing procedure in clinical situation. The reduced friction coefficient in hard DLC layer was not effective to prevent screw loosening.en
dc.description.sponsorship이 연구는 서울대학교 발전기금 및 간접연구경비에서 지원되는 연구비에 의하여 수행되었습니다.en
dc.language.isokoen
dc.publisher대한치과보철학회en
dc.subjectRemoval torqueen
dc.subjectAbutment screwen
dc.subjectDiamond Like Carbonen
dc.subjectFriction coefficienten
dc.titleDLC표면 처리에 따른 임플랜트 지대주 나사의 풀림 현상에 관한 연구en
dc.typeArticleen
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share