Publications

Detailed Information

An unexpectedly low Stratus optical coherence tomography false-positive rate in the non-nasal quadrants of Asian eyes: indirect evidence of differing retinal nerve fibre layer thickness profiles according to ethnicity

DC Field Value Language
dc.contributor.authorKim, T W-
dc.contributor.authorKim, T-W-
dc.contributor.authorPark, K H-
dc.contributor.authorKim, D M-
dc.date.accessioned2010-03-25T23:24:24Z-
dc.date.available2010-03-25T23:24:24Z-
dc.date.issued2008-06-05-
dc.identifier.citationBr J Ophthalmol 2008;92(6):735-739en
dc.identifier.issn1468-2079 (Electronic)-
dc.identifier.urihttps://hdl.handle.net/10371/62012-
dc.description.abstractAIMS: To determine the frequency distribution of false-positive Stratus optical coherence tomography (OCT) results of healthy eyes in terms of peripapillary location. METHODS: One eye of each of 137 healthy Korean subjects was included. The false-positive rates (FPRs) relating to retinal nerve fibre layer (RNFL) thickness parameters were determined. RESULTS: Of the 12 clock-hour positions, the 2 and 4 o'clock positions showed the highest FPRs of 5.1% and 4.4%, respectively, and 7, 8 and 11 o'clock had the lowest FPRs of 0% at <5% level. At <1% level, 2 and 6 o'clock had an FPR of 0.7%, while the FPR was 0% for all other clock-hours. The FPRs for quadrant thicknesses at <5% level were: 0.7% for temporal; 0% for superior; 5.1% for nasal; and 2.2% for inferior. At <1% level, the inferior showed the highest FPR of 0.7%, and the other three quadrants 0%. According to line graph analysis, the 80-120 test point sections had FPRs of 4.4-6.6%, while the 0-40 and 210-256 sections were 0-0.7% at <5% level. At <1% level, the 40-60, 90-110 and 200-210 sections had 0.7%, 190-200 section 1.5%, and all other sections 0%. CONCLUSION: The FPR for the non-nasal region was much lower than expected at <5% level. Given that the current OCT normative database is based on a largely non-Asian population, these findings suggest that RNFL thickness profiles may differ according to ethnicity.en
dc.language.isoenen
dc.publisherBMJ Publishing Groupen
dc.subjectDatabases, Factualen
dc.subjectFalse Positive Reactionsen
dc.subjectGlaucoma/*diagnosis/ethnologyen
dc.subjectPhotoreceptor Cells/anatomy & histologyen
dc.subjectReference Valuesen
dc.subjectRetina/*anatomy & histologyen
dc.subjectTomography, Optical Coherence/*methods/standardsen
dc.subjectAsian Continental Ancestry Group-
dc.titleAn unexpectedly low Stratus optical coherence tomography false-positive rate in the non-nasal quadrants of Asian eyes: indirect evidence of differing retinal nerve fibre layer thickness profiles according to ethnicityen
dc.typeArticleen
dc.identifier.doi10.1136/bjo.2007.129502-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share