Publications

Detailed Information

Circummuscular variant of the deep inferior epigastric perforator in breast reconstruction: importance of preoperative multidetector computed tomographic angiography

DC Field Value Language
dc.contributor.authorHeo, Chanyeong-
dc.contributor.authorYoo, Jihan-
dc.contributor.authorMinn, Kyungwon-
dc.contributor.authorKim, Sungwon-
dc.date.accessioned2010-04-07T08:06:42Z-
dc.date.available2010-04-07T08:06:42Z-
dc.date.issued2008-07-30-
dc.identifier.citationAesthetic Plast Surg. 2008 ;32(5):817-9.en
dc.identifier.issn1432-5241 (Electronic)-
dc.identifier.issn0364-216X (Print)-
dc.identifier.urihttps://hdl.handle.net/10371/62654-
dc.description.abstractThe deep inferior epigastric artery perforator is reliable and widely used in breast reconstruction. The anatomy and course of deep inferior epigastric vessels and their branches are relatively constant and well understood. However, some published cases with a direct perforating pattern and no intramuscular traveling were identified. A case involving a circummuscular variant of a deep inferior epigastric artery perforator is described as well as its clinical importance. This apprises clinicians who perform a transverse rectus abdominis muscle free flap procedure that there can be a rare circummuscular pedicle variant and that it is vulnerable to injury.en
dc.language.isoenen
dc.publisherSpringer Verlagen
dc.subjectAdulten
dc.subjectAngiography/*methodsen
dc.subjectBreast Neoplasms/pathology/surgeryen
dc.subjectEpigastric Arteries/*abnormalities/surgeryen
dc.subjectFemaleen
dc.subjectFollow-Up Studiesen
dc.subjectGraft Survivalen
dc.subjectHumansen
dc.subjectMagnetic Resonance Imagingen
dc.subjectMammaplasty/adverse effects/*methodsen
dc.subjectMastectomy, Radical/methodsen
dc.subjectPreoperative Careen
dc.subjectRectus Abdominis/*blood supply/surgeryen
dc.subjectRisk Assessmenten
dc.subjectSentinel Lymph Node Biopsy/methodsen
dc.subjectSurgical Flaps/blood supplyen
dc.subjectTreatment Outcomeen
dc.subjectWound Healingen
dc.subjectTomography, X-Ray Computed-
dc.titleCircummuscular variant of the deep inferior epigastric perforator in breast reconstruction: importance of preoperative multidetector computed tomographic angiographyen
dc.typeArticleen
dc.contributor.AlternativeAuthor허찬영-
dc.contributor.AlternativeAuthor유지한-
dc.contributor.AlternativeAuthor민경원-
dc.contributor.AlternativeAuthor김성권-
dc.identifier.doi10.1007/s00266-008-9219-6-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share