Publications
Detailed Information
Intraocular lens power calculation in high myopic eyes with previous radial keratotomy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Han, Eui Seok | - |
dc.contributor.author | Lee, Jin Hak | - |
dc.date.accessioned | 2010-07-06T06:44:09Z | - |
dc.date.available | 2010-07-06T06:44:09Z | - |
dc.date.issued | 2006-09-26 | - |
dc.identifier.citation | J Refract Surg. 2006;22(7):713-716 | en |
dc.identifier.issn | 1081-597X (Print) | - |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=16995555 | - |
dc.identifier.uri | https://hdl.handle.net/10371/68335 | - |
dc.description.abstract | PURPOSE: To determine an accurate method of intraocular lens (IOL) power calculation in highly myopic eyes with previous radial keratotomy (RK). METHODS: Five eyes that had undergone RK with preoperative myopia >-14.0 diopters (D) were studied retrospectively. The keratometric values obtained with the clinical history method, contact lens over-refraction method, conventional keratometry, adjusted keratometry, and Orbscan II were compared to the true keratometric value calculated retrospectively with the SRK/T formula. RESULTS: The true keratometric value was closest to that from the contact lens over-refraction method in one eye and to the flatter keratometric value between simulated keratometry (Sim K) and the 3-mm diameter central zone mean keratometric value obtained with axial keratometric power map of Orbscan II in four eyes. CONCLUSIONS: The flatter keratometric value between Sim K and the 3-mm zone mean keratometric value from Orbscan II was closest to the true postoperative RK keratometric value of the central cornea. | en |
dc.language.iso | en | en |
dc.publisher | Slack | en |
dc.subject | Adult | en |
dc.subject | Corneal Topography | en |
dc.subject | Female | en |
dc.subject | Humans | en |
dc.subject | Lens Implantation, Intraocular | en |
dc.subject | Myopia/*surgery | en |
dc.subject | Retrospective Studies | en |
dc.subject | Keratotomy, Radial | - |
dc.subject | Lenses, Intraocular | - |
dc.subject | Optics and Photonics | - |
dc.subject | Phacoemulsification | - |
dc.title | Intraocular lens power calculation in high myopic eyes with previous radial keratotomy | en |
dc.type | Article | en |
dc.contributor.AlternativeAuthor | 한의석 | - |
dc.contributor.AlternativeAuthor | 이진학 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.