Development and Implantation of Pendulum-Type Moving Actuator Total Artificial Heart (Korean Heart) for Human-size Animal : 원추형 이동작동기 방식 완전 인공심장의 개발 및 동물 실험
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Min, Byoung Goo | - |
dc.contributor.author | Kim, Hee Chan | - |
dc.contributor.author | Lee, Sang Hoon | - |
dc.contributor.author | Chang, Jun Kuen | - |
dc.contributor.author | Choi, Jin Wook | - |
dc.contributor.author | Ryu, Gyu Ha | - |
dc.contributor.author | Kim, In Young | - |
dc.contributor.author | Jung, Dae Young | - |
dc.contributor.author | Kim, Jong Won | - |
dc.contributor.author | Seo, Kyung Phil | - |
dc.contributor.author | Rho, Joon Ryang | - |
dc.contributor.author | Ahn, Hyuk | - |
dc.date.accessioned | 2009-08-20T05:15:39Z | - |
dc.date.available | 2009-08-20T05:15:39Z | - |
dc.date.issued | 1990-06 | - |
dc.identifier.citation | Seoul J Med, Vol.31 No.2, pp. 129-135 | - |
dc.identifier.issn | 0582-6802 | - |
dc.identifier.uri | https://hdl.handle.net/10371/7311 | - |
dc.description.abstract | A new version of a moving actuator electromechanical total artificial heart was
designed to improve the total efficiency, durability, and fit inside the thoracic cavity. Compared with our present type of rolling-cylinder actuator, this new model has a pendulum- type actuator with reciprocating motion around a fixed circular path connected through the gear mechanisms to the motor. By using this mechanism, efficiency and "durability improved by replacing the sliding mechanism with rolling contact elements. Also, the height of the pump decreased from 9 cm to 7 cm with a static stroke volume of 65 cc. With this new pump, we performed two animal experiments. We also evaluated the engineering feasibility of implanting this pump into a small, human-size animal (less than 70 Kg). | - |
dc.language.iso | en | - |
dc.publisher | Seoul National University College of Medicine | - |
dc.subject | Moving actuator | - |
dc.subject | Pendulum-type pump | - |
dc.subject | Tether-free | - |
dc.subject | Human chest cage | - |
dc.title | Development and Implantation of Pendulum-Type Moving Actuator Total Artificial Heart (Korean Heart) for Human-size Animal | - |
dc.title.alternative | 원추형 이동작동기 방식 완전 인공심장의 개발 및 동물 실험 | - |
dc.type | SNU Journal | - |
dc.contributor.AlternativeAuthor | 민병구 | - |
dc.contributor.AlternativeAuthor | 김희찬 | - |
dc.contributor.AlternativeAuthor | 이상훈 | - |
dc.contributor.AlternativeAuthor | 장준근 | - |
dc.contributor.AlternativeAuthor | 최진욱 | - |
dc.contributor.AlternativeAuthor | 유규하 | - |
dc.contributor.AlternativeAuthor | 김인영 | - |
dc.contributor.AlternativeAuthor | 정대영 | - |
dc.contributor.AlternativeAuthor | 김종원 | - |
dc.contributor.AlternativeAuthor | 서경필 | - |
dc.contributor.AlternativeAuthor | 노준량 | - |
dc.contributor.AlternativeAuthor | 안혁 | - |
dc.citation.journaltitle | 서울 의대 잡지 | - |
dc.citation.journaltitle | 서울 의대 학술지 | - |
dc.citation.journaltitle | Seoul Journal of Medicine | - |
dc.citation.endpage | 135 | - |
dc.citation.number | 2 | - |
dc.citation.pages | 129-135 | - |
dc.citation.startpage | 129 | - |
dc.citation.volume | 31 | - |