Publications

Detailed Information

Survival analysis of orthodontic mini-implants

DC Field Value Language
dc.contributor.authorLee, Shin-Jae-
dc.contributor.authorAhn, Sug-Joon-
dc.contributor.authorLee, Jae Won-
dc.contributor.authorKim, Seong-Hun-
dc.contributor.authorKim, Tae-Woo-
dc.date.accessioned2011-10-14T05:26:03Z-
dc.date.available2011-10-14T05:26:03Z-
dc.date.issued2010-02-
dc.identifier.citationAm J Orthod Dentofacial Orthop 2010;137:194-199en
dc.identifier.issn0889-5406-
dc.identifier.urihttps://hdl.handle.net/10371/74151-
dc.description.abstractIntroduction: Survival analysis is useful in clinical research because it focuses on comparing the survival distributions and the identification of risk factors. Our aim in this study was to investigate the survival characteristics and risk factors of orthodontic mini-implants with survival analyses. Methods: One hundred forty-one orthodontic patients (treated from October 1, 2000, to November 29, 2007) were included in this survival study. A total of 260 orthodontic mini-implants that had sandblasted (large grit) and acid-etched screw parts were placed between the maxillary second premolar and the first molar. Failures of the implants were recorded as event data, whereas implants that were removed because treatment ended and those that were not removed during the study period were recorded as censored data. A nonparametric life table method was used to visualize the hazard function, and Kaplan-Meier survival curves were generated to identify the variables associated with implant failure. Prognostic variables associated with implant failure were identified with the Cox proportional hazard model. Results: Of the 260 implants, 22 failed. The hazard function for implant failure showed that the risk is highest immediately after placement. The survival function showed that the median survival time of orthodontic mini-implants is sufficient for relatively long orthodontic treatments. The Cox proportional hazard model identified that increasing age is a decisive factor for implant survival. Conclusions: The decreasing pattern of the hazard function suggested gradual osseointegration of orthodontic mini-implants. When implants are placed in a young patient, special caution is needed to lessen the increased probability of failure, especially immediately after placement.en
dc.language.isoenen
dc.publisherElsevier Massonen
dc.titleSurvival analysis of orthodontic mini-implantsen
dc.typeArticleen
dc.contributor.AlternativeAuthor이신재-
dc.contributor.AlternativeAuthor안석준-
dc.contributor.AlternativeAuthor이재원-
dc.contributor.AlternativeAuthor김성훈-
dc.contributor.AlternativeAuthor김태우-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share