Publications

Detailed Information

Feasibility of Automated Quantification of Regional Disease Patterns Depicted on High-Resolution Computed Tomography in Patients with Various Diffuse Lung Diseases

DC Field Value Language
dc.contributor.authorPark, Sang Ok-
dc.contributor.authorSeo, Joon Beom-
dc.contributor.authorKim, Namkug-
dc.contributor.authorPark, Seong Hoon-
dc.contributor.authorPark, Bum-Woo-
dc.contributor.authorLee, Youngjoo-
dc.contributor.authorKang, Suk-Ho-
dc.contributor.authorLee, Jeongjin-
dc.contributor.authorSung, Yu Sub-
dc.contributor.authorLee, Young Kyung-
dc.date.accessioned2012-03-05T02:30:43Z-
dc.date.available2012-03-05T02:30:43Z-
dc.date.issued2012-03-05-
dc.identifier.citationKOREAN JOURNAL OF RADIOLOGY; Vol.10 5; 455-463-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://hdl.handle.net/10371/75339-
dc.description.abstractObjective: This study was designed to develop an automated system for quantification of various regional disease patterns of diffuse lung diseases as depicted on high-resolution computed tomography (HRICT) and to compare the performance of the automated system with human readers. Materials and Methods: A total of 600 circular regions-of-interest (ROIs), 10 pixels in diameter, were utilized. The 600 ROIs comprised 100 ROIs that represented six typical regional patterns (normal, ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation). The ROIs were used to train the automated classification system based on the use of a Support Vector Machine classifier and 37 features of texture and shape. The performance of the classification system was tested with a 5-fold cross-validation method. An automated quantification system was developed with a moving ROI in the lung area, which helped classify each pixel into six categories. A total of 92 HRCT images obtained from patients with different diseases were used to validate the quantification system. Two radiologists independently classified lung areas of the same CT images into six patterns using the manual drawing function of dedicated software. Agreement between the automated system and the readers and between the two individual readers was assessed. Results: The overall accuracy of the system to classify each disease pattern based on the typical ROIs was 89%. When the quantification results were examined, the average agreement between the system and each radiologist was 52% and 49%, respectively. The agreement between the two radiologists was 67%. Conclusion: An automated quantification system for various regional patterns of diffuse interstitial lung diseases can be used for objective and reproducible assessment of disease severity.-
dc.language.isoen-
dc.publisherKOREAN RADIOLOGICAL SOC-
dc.subjectDiffuse interstitial lung disease-
dc.subjectComputed tomography (CT), quantitative-
dc.subjectComputed tomography (CT), high resolution-
dc.subjectComputed tomography (CT), image processing-
dc.titleFeasibility of Automated Quantification of Regional Disease Patterns Depicted on High-Resolution Computed Tomography in Patients with Various Diffuse Lung Diseases-
dc.typeArticle-
dc.contributor.AlternativeAuthor박상옥-
dc.contributor.AlternativeAuthor서준범-
dc.contributor.AlternativeAuthor김남국-
dc.contributor.AlternativeAuthor박성훈-
dc.contributor.AlternativeAuthor박범우-
dc.contributor.AlternativeAuthor이영주-
dc.contributor.AlternativeAuthor강석호-
dc.contributor.AlternativeAuthor이정진-
dc.contributor.AlternativeAuthor성유섭-
dc.contributor.AlternativeAuthor이영경-
dc.identifier.doi10.3348/kjr.2009.10.5.455-
dc.citation.journaltitleKOREAN JOURNAL OF RADIOLOGY-
dc.description.citedreferenceKim N, 2009, J DIGIT IMAGING, V22, P136, DOI 10.1007/s10278-008-9147-7-
dc.description.citedreferenceLee Y, 2009, COMPUT METH PROG BIO, V93, P206, DOI 10.1016/j.cmpb.2008.10.008-
dc.description.citedreferencePark YS, 2008, INVEST RADIOL, V43, P395-
dc.description.citedreferenceXu Y, 2006, ACAD RADIOL, V13, P969, DOI 10.1016/j.acra.2006.04.017-
dc.description.citedreferenceSumikawa H, 2006, J COMPUT ASSIST TOMO, V30, P244-
dc.description.citedreferenceKo JP, 2004, J THORAC IMAG, V19, P136-
dc.description.citedreferenceSluimer IC, 2003, MED PHYS, V30, P3081, DOI 10.1118/1.1624771-
dc.description.citedreferenceHoffman EA, 2003, ACAD RADIOL, V10, P1104, DOI 10.1016/S1076-6332(03)00330-1-
dc.description.citedreferenceUchiyama Y, 2003, MED PHYS, V30, P2440, DOI 10.1118/1.1597431-
dc.description.citedreferenceScatarige JC, 2003, ACAD RADIOL, V10, P167-
dc.description.citedreferenceUppaluri R, 1999, AM J RESP CRIT CARE, V160, P648-
dc.description.citedreferenceUppaluri R, 1999, AM J RESP CRIT CARE, V159, P519-
dc.description.citedreferenceAshizawa K, 1999, ACAD RADIOL, V6, P2-
dc.description.citedreferenceGay SE, 1998, AM J RESP CRIT CARE, V157, P1063-
dc.description.citedreferenceDelorme S, 1997, INVEST RADIOL, V32, P566-
dc.description.citedreferenceCOLLINS CD, 1994, CLIN RADIOL, V49, P236-
dc.description.citedreferenceHARTLEY PG, 1994, J APPL PHYSIOL, V76, P271-
dc.description.citedreferenceNISHIMURA K, 1993, CHEST, V104, P1149-
dc.description.citedreferenceREMYJARDIN M, 1993, RADIOLOGY, V188, P499-
dc.description.citedreferencePADLEY SPG, 1991, CLIN RADIOL, V44, P222-
dc.description.tc7-
dc.identifier.wosid000269516000005-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share