Publications
Detailed Information
Ubiquitous healthcare service using Zigbee and mobile phone for elderly patients
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hak Jong | - |
dc.contributor.author | Lee, Sun Hee | - |
dc.contributor.author | Ha, Kyoo-Seob | - |
dc.contributor.author | Jang, Hak Chul | - |
dc.contributor.author | Kim, Ju Young | - |
dc.contributor.author | Yoo, Dong Hyun | - |
dc.contributor.author | Chang, Yoon-Seok | - |
dc.contributor.author | Chung, Woo Oung | - |
dc.date.accessioned | 2012-05-23T07:41:24Z | - |
dc.date.available | 2012-05-23T07:41:24Z | - |
dc.date.issued | 2009-03 | - |
dc.identifier.citation | INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS; Vol.78 3; 193-198 | ko_KR |
dc.identifier.issn | 1386-5056 | - |
dc.identifier.uri | https://hdl.handle.net/10371/76346 | - |
dc.description.abstract | Objective: To investigate the efficacy of a u-healthcare service using Zigbee and mobile phone for elderly patients with diabetes mellitus or heart diseases. Materials and methods: From July to October, 2005, 29 patients were enrolled in our study. Two selected u-healthcare items, ECG and blood glucose measurement, were monitored. Twenty patients were provided with ZigBee built-in blood glucometer and mobile phones, and were instructed on using a web service where the measured blood glucose could be transmitted directly to the web and be administrated. Nine patients participated in ECG monitoring, by using a wireless, transmittable ECG recording instrument equipped with ZigBee protocol attached to their chest. Daily average transmission frequency, rate of transmission loss, and error reasons were analyzed. In addition, the patients were asked to score their degree of satisfaction about the sensors and u-healthcare services. Results: The mean transmission frequencies were 2.1 times/day in blood glucose monitoring and 6.1 times/day in ECG. The patients` satisfaction scores of the blood glucometer and service used in this research were 8.59 and 9.01 of 10 points, respectively. The mean satisfaction scores about ECG sensor and ECG monitoring services were 5.79 and 7.29, respectively. Discussion: Despite the many problems still encountered such as technological problems related to sensors and some problems like battery replacement, we could transfer the data of glucometer and ECG sensors to web-server via ZigBee protocol. Authors think the ZigBee could be one of components of wireless u-healthcare systems in the future due to its advantages of lower power consumption. (C) 2008 Elsevier Ireland Ltd. All rights reserved. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | ELSEVIER IRELAND LTD | ko_KR |
dc.subject | Ubiquitous healthcare | ko_KR |
dc.subject | Mobile phone | ko_KR |
dc.subject | Elderly patient | ko_KR |
dc.subject | Electrocardiography (ECG) | ko_KR |
dc.subject | Self monitoring blood glucose (SMBG) | ko_KR |
dc.title | Ubiquitous healthcare service using Zigbee and mobile phone for elderly patients | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 이학종 | - |
dc.contributor.AlternativeAuthor | 이선희 | - |
dc.contributor.AlternativeAuthor | 하규섭 | - |
dc.contributor.AlternativeAuthor | 장학철 | - |
dc.contributor.AlternativeAuthor | 김주영 | - |
dc.contributor.AlternativeAuthor | 장윤석 | - |
dc.contributor.AlternativeAuthor | 유동현 | - |
dc.identifier.doi | 10.1016/j.ijmedinf.2008.07.005 | - |
dc.citation.journaltitle | INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS | - |
dc.description.citedreference | Yoon KH, 2008, DIABETES RES CLIN PR, V79, P256, DOI 10.1016/j.diabres.2007.09.007 | - |
dc.description.citedreference | Kim BS, 2006, IEEE T INF TECHNOL B, V10, P77, DOI 10.1109/TITB.2005.856854 | - |
dc.description.citedreference | Farmer A, 2005, DIABETIC MED, V22, P1372, DOI 10.1111/j.1464-5491.2005.01627.x | - |
dc.description.citedreference | Young RJ, 2005, DIABETES CARE, V28, P278 | - |
dc.description.citedreference | FARMER A, 2005, INFORM PRIM CARE, V13, P171 | - |
dc.description.citedreference | Montori VM, 2004, DIABETES CARE, V27, P1088 | - |
dc.description.citedreference | HAILEY D, 2004, J TELEMED TELECAR S1, V10, P36 | - |
dc.description.citedreference | RUBEL P, 2004, STUD HLTH TECHNOL IN, V108, P123 | - |
dc.description.citedreference | MAROZAS V, 2004, STUD HLTH TECHNOL IN, V105, P337 | - |
dc.description.citedreference | ZHOU HY, 2004, STUDIES HLTH TECHNOL, V105, P112 | - |
dc.description.citedreference | Murata GH, 2003, DIABETES CARE, V26, P1759 | - |
dc.description.citedreference | Magrabi F, 1999, INT J MED INFORM, V54, P145 | - |
dc.description.tc | 9 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.