Publications

Detailed Information

Experimental Bone Biopsies Using Two Bone Biopsy Needles: Quantitative Micro-CT Analysis of Bone Specimens

Cited 4 time in Web of Science Cited 6 time in Scopus
Authors

Park, Eun-Ah; Hong, Sung Hwan; Kim, Kwang Gi; Choi, Ja-Young; Kang, Heung Sik; Shin, Chan Soo

Issue Date
2009-03
Publisher
ELSEVIER SCIENCE INC
Citation
ACADEMIC RADIOLOGY; Vol.16 3; 332-340
Keywords
Micro-computed tomographybone biopsytrabecular thicknessbone histomorphometrymicrostructure
Abstract
Rationale and Objectives. The aim of this study was to investigate whether samples obtained using two kinds of small trephines, 2.4 and 1.8 mm in inner diameter, are sufficient for the quantitative evaluation of metabolic bone disease using micro-computed tomographic (CT) three-dimensional parameter data sets. Materials and Methods. A total of 19 porcine lumbar vertebrae prior to biopsy and biopsy samples from the use of 2.4- and 1.8-mm trephines were examined using micro-CT imaging. For quantitative analysis, seven three-dimensional structural parameters, including trabecular bone volume, trabecular number, trabecular thickness, trabecular separation, the structure model index, the degree of anisotropy, and the trabecular bone pattern factor, were measured using CtAn software. The difference and agreement between the biopsy samples and the baseline vertebrae specimens before biopsy were assessed using paired t tests and Bland-Altman analysis, respectively. Results. There were no significant differences between the 2.4-mm samples and the baseline vertebrae specimens for trabecular bone volume, trabecular thickness, and trabecular number, with mean differences of -0.9%, 2.3%, and -3.1%, respectively; there was no significant difference between the 1.8-mm samples and the baseline vertebrae specimens only for trabecular thickness, with a mean difference of 1.9%. Conclusion. Samples taken from the use of the 2.4-mm trephine were better for quantitative analysis than those from the use of the 1.8-mm trephine and were acceptable for the quantitative evaluation of trabecular bone volume, trabecular thickness, and trabecular number.
ISSN
1076-6332
Language
English
URI
https://hdl.handle.net/10371/76352
DOI
https://doi.org/10.1016/j.acra.2008.09.006
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share