Publications
Detailed Information
Is MRI a reliable tool to locate the electrode after deep brain stimulation surgery? Comparison study of CT and MRI for the localization of electrodes after DBS
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Ji Yeoun | - |
dc.contributor.author | Kim, Jin Wook | - |
dc.contributor.author | Lee, Jee-Young | - |
dc.contributor.author | Lim, Yong Hoon | - |
dc.contributor.author | Kim, Dong Gyu | - |
dc.contributor.author | Paek, Sun Ha | - |
dc.contributor.author | Jeon, Beom Seok | - |
dc.contributor.author | Kim, Cheolyoung | - |
dc.date.accessioned | 2012-06-28T00:27:48Z | - |
dc.date.available | 2012-06-28T00:27:48Z | - |
dc.date.issued | 2010-12 | - |
dc.identifier.citation | ACTA NEUROCHIRURGICA; Vol.152 12; 2029-2036 | ko_KR |
dc.identifier.issn | 0001-6268 | - |
dc.identifier.uri | https://hdl.handle.net/10371/77683 | - |
dc.description.abstract | MRI has been utilized to localize the electrode after deep brain stimulation, but its accuracy has been questioned due to image distortion. Under the hypothesis that MRI is not adequate for evaluation of electrode position after deep brain stimulation, this study is aimed at validating the accuracy of MRI in electrode localization in comparison with CT scan. Sixty one patients who had undergone STN DBS were enrolled for the analysis. Using mutual information technique, CT and MRI taken at 6 months after the operation were fused. The x and y coordinates of the centers of electrodes shown of CT and MRI were compared in the fused images to calculate average difference at five different levels. The difference of the tips of the electrodes, designated as the z coordinate, was also calculated. The average of the distance between the centers of the electrodes in the five levels estimated in the fused image of brain CT and MRI taken at least 6 months after STN DBS was 1.33 mm (0.1-5.8 mm). The average discrepancy of x coordinates for all five levels between MRI and CT was 0.56 +/- 0.54 mm (0-5.7 mm), the discrepancy of y coordinates was 1.06 +/- 0.59 mm (0-3.5 mm), and for the z coordinate, it was 0.98 +/- 0.52 mm (0-3.1 mm) (all p values < 0.001). Notably, the average discrepancy of x coordinates at 3.5 mm below AC-PC level, i.e., at the STN level between MRI and CT, was 0.59 +/- 0.42 mm (0-2.4 mm); the discrepancy of y coordinates was 0.81 +/- 0.47 mm (0-2.9 mm) (p values < 0.001). The results suggest that there was significant discrepancy between the centers of electrodes estimated by CT and MRI after STN DBS surgery. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | SPRINGER WIEN | ko_KR |
dc.subject | CT | ko_KR |
dc.subject | DBS | ko_KR |
dc.subject | Electrode localization | ko_KR |
dc.subject | Parkinson`s disease | ko_KR |
dc.subject | MRI | ko_KR |
dc.subject | Image fusion | ko_KR |
dc.title | Is MRI a reliable tool to locate the electrode after deep brain stimulation surgery? Comparison study of CT and MRI for the localization of electrodes after DBS | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 이지연 | - |
dc.contributor.AlternativeAuthor | 김진욱 | - |
dc.contributor.AlternativeAuthor | 이지영 | - |
dc.contributor.AlternativeAuthor | 임용훈 | - |
dc.contributor.AlternativeAuthor | 김철영 | - |
dc.contributor.AlternativeAuthor | 김동규 | - |
dc.contributor.AlternativeAuthor | 전범석 | - |
dc.contributor.AlternativeAuthor | 백선하 | - |
dc.identifier.doi | 10.1007/s00701-010-0779-2 | - |
dc.citation.journaltitle | ACTA NEUROCHIRURGICA | - |
dc.description.citedreference | Lee JY, 2010, CLIN NEUROL NEUROSUR, V112, P47, DOI 10.1016/j.clineuro.2009.10.008 | - |
dc.description.citedreference | Tagliati M, 2009, NEUROIMAGE, V47, pT53, DOI 10.1016/j.neuroimage.2009.04.044 | - |
dc.description.citedreference | Paek SH, 2008, NEUROSURGERY, V63, P925, DOI 10.1227/01.NEU.0000334045.43940.FB | - |
dc.description.citedreference | Lee JY, 2008, J KOREAN NEUROSURG S, V44, P26, DOI 10.3340/jkns.2008.44.1.26 | - |
dc.description.citedreference | Tisch S, 2007, J NEUROL NEUROSUR PS, V78, P1314, DOI 10.1136/jnnp.2006.109694 | - |
dc.description.citedreference | McClelland S, 2007, J CLIN NEUROSCI, V14, P791, DOI 10.1016/j.jocn.2006.03.032 | - |
dc.description.citedreference | Martinez-Santiesteban FM, 2007, PHYS MED BIOL, V52, P2073, DOI 10.1088/0031-9155/52/8/003 | - |
dc.description.citedreference | Pinto S, 2007, NEUROSURGERY, V60, P285, DOI 10.1227/01.NEU.0000255353.64077.A8 | - |
dc.description.citedreference | Vergani F, 2007, SURG NEUROL, V67, P140, DOI 10.1016/j.surneu.2006.06.054 | - |
dc.description.citedreference | Pollo C, 2007, J NEUROSURG, V106, P36 | - |
dc.description.citedreference | Breit S, 2006, NEUROSURGERY, V58, P83, DOI 10.1227/01.NEU.0000192689.00427.C2 | - |
dc.description.citedreference | COYNE T, 2006, ACT NEUR S, V99, P49 | - |
dc.description.citedreference | Winkler D, 2005, J NEUROL NEUROSUR PS, V76, P1161, DOI 10.1136/jnnp.2004.047373 | - |
dc.description.citedreference | Simon SL, 2005, STEREOT FUNCT NEUROS, V83, P1, DOI 10.1159/000083861 | - |
dc.description.citedreference | Bittar RG, 2005, J CLIN NEUROSCI, V12, P12, DOI 10.1016/j.jocn.2004.03.025 | - |
dc.description.citedreference | MCCLELLAND S, 2005, NEUROSURG FOCUS, V19, pE12 | - |
dc.description.citedreference | Rezai AR, 2004, INVEST RADIOL, V39, P300, DOI 10.1097/01.rli.0000124940.02340.ab | - |
dc.description.citedreference | Pollo C, 2004, ACTA NEUROCHIR, V146, P161, DOI 10.1007/s00701-003-0181-4 | - |
dc.description.citedreference | Spiegel J, 2003, J NEUROSURG, V99, P772 | - |
dc.description.citedreference | Counelis GJ, 2003, MOVEMENT DISORD, V18, P1062, DOI 10.1002/mds.10489 | - |
dc.description.citedreference | Hamel W, 2003, J NEUROL NEUROSUR PS, V74, P1036 | - |
dc.description.citedreference | Yelnik J, 2003, J NEUROSURG, V99, P89 | - |
dc.description.citedreference | RAMPINI PM, 2003, J NEUROSURG SCI, V47, P33 | - |
dc.description.citedreference | Uitti RJ, 2002, NEUROSURGERY, V51, P1423, DOI 10.1227/01.NEU.0000036030.73566.4B | - |
dc.description.citedreference | Saint-Cyr JA, 2002, J NEUROSURG, V97, P1152 | - |
dc.description.citedreference | Voges J, 2002, J NEUROSURG, V96, P269 | - |
dc.description.citedreference | Holtzheimer PE, 1999, NEUROSURGERY, V45, P290 | - |
dc.description.citedreference | Rezai AR, 1999, J NEUROSURG, V90, P583 | - |
dc.description.citedreference | Tronnier VM, 1999, NEUROSURGERY, V44, P118 | - |
dc.description.citedreference | Starr PA, 1998, NEUROSURGERY, V43, P989 | - |
dc.description.citedreference | Limousin P, 1998, NEW ENGL J MED, V339, P1105 | - |
dc.description.citedreference | Dormont D, 1997, AM J NEURORADIOL, V18, P1093 | - |
dc.description.citedreference | Maes F, 1997, IEEE T MED IMAGING, V16, P187, DOI 10.1109/42.563664 | - |
dc.description.citedreference | LIMOUSIN P, 1995, LANCET, V345, P91 | - |
dc.description.citedreference | SUMANAWEERA TS, 1994, NEUROSURGERY, V35, P696 | - |
dc.description.citedreference | ZHANG JX, 1993, AM J NEURORADIOL, V14, P497 | - |
dc.description.citedreference | BROOKS ML, 1992, EPILEPSIA, V33, P888 | - |
dc.description.citedreference | KONDZIOLKA D, 1992, NEUROSURGERY, V30, P402 | - |
dc.description.tc | 4 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.