Development of portable breast self-examination device using enhanced tactile feedback

DC Field Value Language
dc.contributor.authorRyu, J.-
dc.contributor.authorHeo, M. S.-
dc.contributor.authorKim, H. C.-
dc.date.accessioned2012-06-29T00:27:46Z-
dc.date.available2012-06-29T00:27:46Z-
dc.date.issued2010-12-
dc.identifier.citationELECTRONICS LETTERS; Vol.46 25; 1651-1652ko_KR
dc.identifier.issn0013-5194-
dc.identifier.urihttps://hdl.handle.net/10371/77841-
dc.description.abstractA simple tactile imaging system for detecting possible breast lumps is proposed. The breast cancer detection system (BCDS) consists of a palm-sized, portable, wireless scanning probe with a nine-force sensor array, a web camera, and a PC program to display the location and stiffness of hard breast lesions based on tactile pressure profiles. The results of performance evaluation tests using various breast phantoms demonstrated that palpable abnormalities larger than 5 mm located at depths less than 25 mm can be detected accurately. It is expected that this low-priced BCDS will extensively benefit all adults and ubiquitous healthcare services who apply regular breast self-examination by providing remote magnified palpation with enhanced tactile sensitivity.ko_KR
dc.description.sponsorshipThis work was supported by the National Research
Foundation of Korea (NRF) grant funded by the Korea government
(MEST) (no. 2005-2001287).
ko_KR
dc.language.isoenko_KR
dc.publisherINST ENGINEERING TECHNOLOGY-IETko_KR
dc.titleDevelopment of portable breast self-examination device using enhanced tactile feedbackko_KR
dc.typeArticleko_KR
dc.identifier.doi10.1049/el.2010.2711-
dc.citation.journaltitleELECTRONICS LETTERS-
dc.description.citedreferenceGuth U, 2008, CANCER DETECT PREV, V32, P224, DOI 10.1016/j.cdp.2008.04.002-
dc.description.citedreferenceKaufman CS, 2006, AM J SURG, V192, P444, DOI 10.1016/j.amjsurg.2006.06.006-
dc.description.citedreferenceSaslow D, 2004, CA-CANCER J CLIN, V54, P327-
dc.description.citedreferenceSUR P, 2001, CA CANC J CLIN, V51, P268-
dc.description.citedreferenceSARVAZYAN T, 1998, P 20 ANN INT C IEEE, V20-
dc.description.citedreferenceOMATA S, 1992, SENSOR ACTUAT A-PHYS, V35, P9-
dc.description.citedreferenceHAAGENSEN CD, 1986, DIS BREAST-
dc.description.tc0-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share