Publications
Detailed Information
Usefulness of concurrent reading using thin-section and thick-section CT images in subcentimetre solitary pulmonary nodules
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, H. Y. | - |
dc.contributor.author | Goo, J. M. | - |
dc.contributor.author | Lee, H. J. | - |
dc.contributor.author | Lee, C. H. | - |
dc.contributor.author | Park, E. -A. | - |
dc.contributor.author | Im, J. -G. | - |
dc.contributor.author | Park, C. M. | - |
dc.date.accessioned | 2012-07-02T01:12:17Z | - |
dc.date.available | 2012-07-02T01:12:17Z | - |
dc.date.issued | 2009-02 | - |
dc.identifier.citation | CLINICAL RADIOLOGY; Vol.64(2); 127-132 | ko_KR |
dc.identifier.issn | 0009-9260 | - |
dc.identifier.uri | https://hdl.handle.net/10371/78033 | - |
dc.description.abstract | AIM: To evaluate the differences in the characterization and recommendation for follow-up of subcentimetre solitary pulmonary nodules (SSPNs) between 5 and 1 mm section CT, and to compare the assessments generated by four radiologists MATERIALS AND METHODS: Five hundred and twenty-nine patients who had SSPNs on chest CT reconstructed using both 5 and 1 mm sections were enrolled. Two image subsets of 5 and 1 mm CT images of each nodule were interpreted independently by four radiologists. Nodule size, consistency (solid, partly solid, non-solid), the presence of calcification, and recommendations for follow-up were evaluated. If a non-calcified solid nodule was confirmed using CT, recommendation for follow-up was based on Fleischner Society guidelines. Data assessed by each radiologist were compared, and interobserver agreements were determined using the intraclass correlation coefficients and kappa value. RESULTS: Using 1 mm CT images, the nodule sizes were significantly larger than on 5 mm CT images (paired t-test, p < 0.01). The presence of calcification and nodule consistency were significantly different between 5 and 1 mm CT images (McNemar test for the presence of calcification, p < 0.01; Wilcoxon signed test for nodule consistency, p < 0.01). On 1 mm CT images there was significantly higher agreement regarding nodule consistency than on 5 mm CT (kappa - 0.78 and 0.67, respectively). CONCLUSIONS: Concurrent use of thin-section and thick-section CT can provide more accurate nodule assessment and higher interobserver agreement in SSPN. (c) 2008 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | W B SAUNDERS CO LTD | ko_KR |
dc.title | Usefulness of concurrent reading using thin-section and thick-section CT images in subcentimetre solitary pulmonary nodules | ko_KR |
dc.type | Article | ko_KR |
dc.identifier.doi | 10.1016/j.crad.2008.09.003 | - |
dc.citation.journaltitle | CLINICAL RADIOLOGY | - |
dc.description.citedreference | Gierada DS, 2008, RADIOLOGY, V246, P265 | - |
dc.description.citedreference | Saito H, 2007, LUNG CANCER, V58, P348, DOI 10.1016/j.lungcan.2007.06.018 | - |
dc.description.citedreference | Park CM, 2007, RADIOGRAPHICS, V27, P391, DOI 10.1148/rg.272065061 | - |
dc.description.citedreference | *NEW YORK EARL LUN, 2007, RADIOLOGY, V243, P239 | - |
dc.description.citedreference | MacMahon H, 2005, RADIOLOGY, V237, P395, DOI 10.1148/radiol.2372041887 | - |
dc.description.citedreference | Kim JS, 2005, RADIOLOGY, V236, P295, DOI 10.1148/radiol.2361041288 | - |
dc.description.citedreference | Goo JM, 2005, RADIOLOGY, V235, P850, DOI 10.1148/radiol.2353040737 | - |
dc.description.citedreference | Li F, 2004, RADIOLOGY, V233, P793, DOI 10.1148/radiol.2333031018 | - |
dc.description.citedreference | Wormanns D, 2004, EUR RADIOL, V14, P1380, DOI 10.1007/s00330-004-2335-z | - |
dc.description.citedreference | Brenner DJ, 2004, RADIOLOGY, V231, P440, DOI 10.1148/radiol.2312030880 | - |
dc.description.citedreference | Winer-Muram HT, 2003, RADIOLOGY, V229, P184, DOI 10.1148/radiol.2291020859 | - |
dc.description.citedreference | Henschke CI, 2002, AM J ROENTGENOL, V178, P1053 | - |
dc.description.citedreference | Nakata M, 2002, CHEST, V121, P1464 | - |
dc.description.citedreference | Diederich S, 2002, RADIOLOGY, V222, P773, DOI 10.1148/radiol.2223010490 | - |
dc.description.citedreference | Aberle DR, 2001, J THORAC IMAG, V16, P65 | - |
dc.description.citedreference | Hasegawa M, 2000, BRIT J RADIOL, V73, P1252 | - |
dc.description.citedreference | Henschke CI, 1999, LANCET, V354, P99 | - |
dc.description.citedreference | ZWIREWICH CV, 1991, RADIOLOGY, V179, P469 | - |
dc.description.citedreference | ZERHOUNI EA, 1986, RADIOLOGY, V160, P319 | - |
dc.description.citedreference | SHROUT PE, 1979, PSYCHOL BULL, V86, P420 | - |
dc.description.tc | 6 | - |