Publications
Detailed Information
Intratarsal Fixation at the Same Level as the Skin Incision to Reduce Asymmetric Double Eyelids Evaluation of Symmetry Using Photogrammetry
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Han, Kihwan | - |
dc.contributor.author | Yeo, Hyeonjung | - |
dc.contributor.author | Choi, Tae Hyun | - |
dc.contributor.author | Son, Daegu | - |
dc.contributor.author | Kim, Jun Hyung | - |
dc.date.accessioned | 2012-07-03T02:18:24Z | - |
dc.date.available | 2012-07-03T02:18:24Z | - |
dc.date.issued | 2010-03 | - |
dc.identifier.citation | ANNALS OF PLASTIC SURGERY; Vol.64 3; 265-269 | ko_KR |
dc.identifier.issn | 0148-7043 | - |
dc.identifier.uri | https://hdl.handle.net/10371/78192 | - |
dc.description.abstract | One of the most common complications of double eyelid operations is asymmetry. To reduce asymmetry, we fixed the dermis to the tarsal plate at the same level as the skin incision, and objectively evaluated the symmetry of the height using photogrammetry. Of 30 patients who had double eyelid operations by the intratarsal fixation technique, 15 patients completed a minimum follow-up of 6 months. After the skin incision and removal of the orbicularis oculi muscle and the orbital fat, the pretarsal fat pad was excised to expose the superior portion of the tarsal plate. The 3 fixation points were marked on the tarsal plate at the same level with the skin incision using a spreading caliper. The dermis was fixed to the marked points of the tarsal plate and the skin was closed. The height of the double eyelid was measured by clinical photography at 4 points when the eyes were opened and at 3 points when the eyes were closed. The height proportional index at each point was obtained by dividing the height of the left double eyelid by that of the right double eyelid. We compared each height proportional index with "1" to evaluate the symmetry of both double eyelids using a paired t test. The follow-up period was an average of 9.0 months. The mean height proportional indices were 0.97 (a), 0.96 (b), 0.98 (c), 1.08 (d), 0.97 (e), 1.02 (f), and 1.13 (g). According to a paired t test, the height of the left double eyelid was not different from that of the right double eyelid. Intratarsal fixation, along with other previously known methods, decreases asymmetric double eyelids. | ko_KR |
dc.language.iso | en | ko_KR |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | ko_KR |
dc.subject | double eyelids | ko_KR |
dc.subject | intratarsal fixation | ko_KR |
dc.subject | photogrammetry | ko_KR |
dc.title | Intratarsal Fixation at the Same Level as the Skin Incision to Reduce Asymmetric Double Eyelids Evaluation of Symmetry Using Photogrammetry | ko_KR |
dc.type | Article | ko_KR |
dc.contributor.AlternativeAuthor | 한기환 | - |
dc.contributor.AlternativeAuthor | 여현정 | - |
dc.contributor.AlternativeAuthor | 최태현 | - |
dc.contributor.AlternativeAuthor | 손대구 | - |
dc.contributor.AlternativeAuthor | 김전형 | - |
dc.identifier.doi | 10.1097/SAP.0b013e3181b022e3 | - |
dc.citation.journaltitle | ANNALS OF PLASTIC SURGERY | - |
dc.description.citedreference | KWON H, 2007, J KOREAN SOC PLAST R, V34, P24 | - |
dc.description.citedreference | Chen SHT, 2004, PLAST RECONSTR SURG, V114, P1270, DOI 10.1097/01.PRS.0000135951.55118.59 | - |
dc.description.citedreference | KIM SK, 2002, J KOREAN SOC AESTHET, V8, P106 | - |
dc.description.citedreference | CHEN WP, 2001, OCULOPLASTIC SURG ES, P211 | - |
dc.description.citedreference | Kim YW, 2000, PLAST RECONSTR SURG, V106, P1399 | - |
dc.description.citedreference | SHIN KS, 1996, J KOREAN SOC PLAST R, V1, P75 | - |
dc.description.citedreference | FLOWERS RS, 1993, CLIN PLAST SURG, V20, P193 | - |
dc.description.citedreference | SONG IC, 1991, PROBL PLAST RECONSTR, V1, P542 | - |
dc.description.citedreference | WENG CJ, 1989, PLAST RECONSTR SURG, V83, P622 | - |
dc.description.citedreference | HIN LC, 1985, ANN PLAS SURG, V14, P523 | - |
dc.description.citedreference | HIN LC, 1981, ANN PLAST SURG, V7, P362 | - |
dc.description.citedreference | CONVERSE JM, 1977, RECONSTRUCTIVE PLAST, P864 | - |
dc.description.tc | 0 | - |
- Appears in Collections:
- Files in This Item:
- There are no files associated with this item.
Item View & Download Count
Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.