Publications

Detailed Information

The effect of obturator bulb height on speech in maxillectomy patients

DC Field Value Language
dc.contributor.authorKwon, H.B.-
dc.contributor.authorChang, S.W.-
dc.contributor.authorLee, Seok Hyoung-
dc.date.accessioned2013-01-21T04:42:51Z-
dc.date.available2013-01-21T04:42:51Z-
dc.date.issued2011-
dc.identifier.citationJournal of Oral Rehabilitation; Vol.38, No.3, pp.185-195ko_KR
dc.identifier.issn1365-2842-
dc.identifier.urihttps://hdl.handle.net/10371/80847-
dc.descriptionThe definitive version is available at www.blackwell-synergy.comko_KR
dc.description.abstractThe purpose of this study was to compare the speech function of low height bulb obturators with that of high height bulb obturators. Thirteen maxillectomy patients, who underwent post-operative prosthodontic rehabilitations, were included. Two obturators of the same design except for different bulb heights were fabricated for each maxillectomy patient. One of the two obturators had high bulb design and the other had low bulb design. After one of the obturators was used for a period of 3weeks, the patient`s speaking functions were evaluated by measuring nasalance scores, formant frequencies, and vowel working space areas. The same procedures were repeated with the second obturator following another 3-week period of usage. In addition, the effect of delivery sequence and anatomic conditions related to maxillectomy were analysed. The results demonstrated that the nasalance scores with the low bulb obturators were significantly higher than those with the high bulb obturators. There were no significant differences in formant frequencies based on the bulb height of the obturators. The vowel working spaces for the two obturators were similar in shape and there were no significant differences between the vowel working space areas created by the two obturators. The delivery sequence affected the results. However, there were no significant differences related to the other anatomical variables. Although low bulb obturators might function similarly with high bulb obturators in terms of the articulation of speech, they would exhibit a difficulty in controlling hypernasality in maxillectomy patients. ⓒ 2010 Blackwell Publishing Ltd.ko_KR
dc.language.isoenko_KR
dc.publisherBlackwell Publishing Ltdko_KR
dc.subjectAcoustic analysisko_KR
dc.subjectSpeechko_KR
dc.subjectObturator heightko_KR
dc.subjectObturatorko_KR
dc.subjectNasalanceko_KR
dc.subjectMaxillectomyko_KR
dc.titleThe effect of obturator bulb height on speech in maxillectomy patientsko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor권호범-
dc.contributor.AlternativeAuthor장석우-
dc.contributor.AlternativeAuthor이석형-
dc.identifier.doi10.1111/j.1365-2842.2010.02139.x-
dc.citation.journaltitleJournal of Oral Rehabilitation-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share