Fractal analysis of mandibular trabecular bone: Optimal tile sizes for the tile counting method

Cited 0 time in Web of Science Cited 14 time in Scopus
Authors

Huh, Kyung-Hoe; Baik, Jee-Seon; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul; Lee, Seung-Pyo; Lee, Sun-Bok; Lee, Sam-Sun

Issue Date
2011
Publisher
Korean Academy of Oral and Maxillofacial Radiology
Citation
Imaging Science in Dentistry; Vol.41, No.2, pp.71-78
Keywords
Dental digital radiographFractalsTrabecular meshwork
Abstract
Purpose: This study was performed to determine the optimal tile size for the fractal dimension of the mandibular trabecular bone using a tile counting method. Materials and Methods: Digital intraoral radiographic images were obtained at the mandibular angle, molar, premolar, and incisor regions of 29 human dry mandibles. After preprocessing, the parameters representing morphometric characteristics of the trabecular bone were calculated. The fractal dimensions of the processed images were analyzed in various tile sizes by the tile counting method. Results: The optimal range of tile size was 0.132 mm to 0.396 mm for the fractal dimension using the tile counting method. The sizes were closely related to the morphometric parameters. Conclusion: The fractal dimension of mandibular trabecular bone, as calculated with the tile counting method, can be best characterized with a range of tile sizes from 0.132 to 0.396 mm. ⓒ 2011 by Korean Academy of Oral and Maxillofacial Radiology.
ISSN
2233-7822
Language
English
URI
https://hdl.handle.net/10371/80891
DOI
https://doi.org/10.5624/isd.2011.41.2.71