Risk of internal carotid artery injury during C1 screw placement: analysis of 160 computed tomography angiograms

DC Field Value Language
dc.contributor.authorEstillore, Romel P.-
dc.contributor.authorBuchowski, Jacob M.-
dc.contributor.authorMinh, Do Van-
dc.contributor.authorPark, Kun-Woo-
dc.contributor.authorChang, Bong-Soon-
dc.contributor.authorLee, Choon-Ki-
dc.contributor.authorRiew, K. Daniel-
dc.contributor.authorYeom, Jin S.-
dc.creator염진섭-
dc.date.accessioned2013-01-25T06:24:34Z-
dc.date.available2013-01-25T06:24:34Z-
dc.date.issued2011-04-
dc.identifier.citationSPINE JOURNAL Vol.11 No.4, pp. 316-323-
dc.identifier.issn1529-9430-
dc.identifier.urihttps://hdl.handle.net/10371/81097-
dc.description.abstractBACKGROUND CONTEXT: Injury to the internal carotid artery (ICA) is a potentially catastrophic complication of C1-lateral mass (C1-LM) or C1-C2 transarticular screw insertion.PURPOSE: This study was designed to determine the risk of injury to the ICA during placement of these screws using computed tomography angiography (CTA).STUDY DESIGN: Radiographic analysis using CTA.PATIENT SAMPLE: One hundred sixty CTAs were examined, for a total of 320 ICAs.OUTCOME MEASURES: Not applicable.METHODS: Fine-cut intravenous CTAs with multiplanar and three-dimensional reconstruction were reviewed. The position of the ICA in relation to the anterior cortex (AC) of C1, anterior end of the anterior tubercle (AT), and medial margin of the transverse foramen (TF) was measured bilaterally in three ascending and equidistant levels of the C1-AT.RESULTS: The position of the ICA in relation to C1 was variable. The average distance between the ICA and the AC of C1 was only 3.7 mm. Furthermore, 96% of the time the posterior margin of the ICA was located posterior to the anteriormost aspect of the anterior C1 tubercle (average distance, 5.4 mm), making the ICA vulnerable to damage if a drill, tap, or screw was inserted to the depth of the anteriormost portion of the AT as seen on a lateral fluoroscopic or radiographic view. The medial margin of the ICA was located medial to the TF (a location potentially vulnerable to injury with bicortical screw placement) less often at the caudal aspect of the C1-AT (54%) than at its middle or cranial aspect (74% and 75%, respectively). No ICAs were located anterior to the medial 30% of the C1-LM or more medially.CONCLUSIONS: Bicortical C1-LM or C1-C2 transarticular screw placement carries a potential risk of ICA injury. Given the wide variation in ICA location relative to C1, if bicortical C1 fixation is required, preoperative CTA should be considered to determine the optimal screw trajectory. In general, inferomedially angulated C1-LM screws appear to be safer with respect to the ICA injury than other potential trajectories. (C) 2011 Elsevier Inc. All rights reserved.en
dc.language.isoenen
dc.publisherELSEVIER SCIENCE INCen
dc.subject복합학en
dc.subjectInternal carotid artery-
dc.subjectVascular injury-
dc.subjectComplication-
dc.subjectC1 lateral mass screw placement-
dc.subjectTransarticular C1.C2 screw placement-
dc.titleRisk of internal carotid artery injury during C1 screw placement: analysis of 160 computed tomography angiogramsen
dc.typeArticle-
dc.contributor.AlternativeAuthor박근우-
dc.contributor.AlternativeAuthor장봉순-
dc.contributor.AlternativeAuthor이준기-
dc.contributor.AlternativeAuthor염진섭-
dc.identifier.doi10.1016/j.spinee.2011.03.009-
dc.description.srndOAIID:oai:osos.snu.ac.kr:snu2011-01/102/0000004226/4-
dc.description.srndSEQ:4-
dc.description.srndPERF_CD:SNU2011-01-
dc.description.srndEVAL_ITEM_CD:102-
dc.description.srndUSER_ID:0000004226-
dc.description.srndADJUST_YN:Y-
dc.description.srndEMP_ID:A076317-
dc.description.srndDEPT_CD:801-
dc.description.srndCITE_RATE:3.29-
dc.description.srndFILENAME:E032T_TSJ-2011_Estillore_Risk of internal carotid artery injury during C1 screw placement.pdf-
dc.description.srndDEPT_NM:의학과-
dc.description.srndEMAIL:highcervical@gmail.com-
dc.description.srndSCOPUS_YN:Y-
dc.description.srndCONFIRM:Y-
dc.identifier.srnd2011-01/102/0000004226/4-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share