Publications

Detailed Information

Promotion of Osseointegration of Anodized Titanium Implants with a 1 alpha,25-Dihydroxyvitamin D3 Submicron Particle Coating

DC Field Value Language
dc.contributor.authorCho, Young-Jin-
dc.contributor.authorHeo, Seong-Joo-
dc.contributor.authorKoak, Jai-Young-
dc.contributor.authorKim, Seong-Kyun-
dc.contributor.authorLee, Joo-Hee-
dc.contributor.authorLee, Shin-Jae-
dc.date.accessioned2013-05-01T00:18:56Z-
dc.date.available2013-05-01T00:18:56Z-
dc.date.issued2011-12-
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants, Vol.26, No.6, pp. 1225-1232ko_KR
dc.identifier.issn0882-2786-
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/pubmed/22167427-
dc.identifier.urihttps://hdl.handle.net/10371/82365-
dc.description.abstractPurpose: A biochemical approach to implant surface modification may offer an alternative to physicochemical and morphologic methods for obtaining desirable bone-implant interfaces. The objective of this study was to investigate the bone tissue response to anodized titanium implant surfaces coated with a poly(D, L-lactide-co-glycolide) (PLGA) solution mixed with 1 alpha,25-diydroxyvitamin D3 (1 alpha, 25-(OH)(2)D3) via an electrospray technique. Materials and Methods: Threaded implants were manufactured and anodized under 300 V at 660 Hz for 3 minutes (control group). Half of the implants were then coated with 0.15 mL of the PLGA/1 alpha,25-(OH)(2)D3 solution (5 mu g/implant) via electrospray (experimental group). Surface topography was evaluated using field-emission scanning electron microscopy and optical interferometry. Forty-eight implants (12 implants per group per healing period) were surgically placed in random sites in the tibiae of 12 New Zealand white rabbits. After 4 and 12 weeks of healing, undecalcified ground sections were subjected to histologic and histomorphometric analyses. Results: At week 4, the mean bone-to-implant contact ratio (BIC%) over the entire length of the implant in the experimental group was 37.08% +/- 10.18%, versus 28.01% +/- 8.70% in the control group. The mean BIC% value in the first four consecutive threads of the experimental group was 48.64% +/- 15.92%, compared to 36.11% +/- 13.49% in the control group (P < .05). At week 12, the mean overall BIC% values were 39.10% +/- 7.68% in the experimental group and 29.53% +/- 9.49% in the control group. The mean BIC% value in the first four consecutive threads of the experimental group was 51.80% +/- 16.41%, versus 37.35% +/- 11.77% in the control group (P < .05). Conclusion: The current study demonstrated that the PLGA/1 alpha, 25-(OH)(2)D3 solution coating resulted in submicron-sized particles, which may stimulate bone formation adjacent to the surface of implants inserted into bone. Int J Oral Maxillofac Implants 2011;26:1225-1232ko_KR
dc.language.isoenko_KR
dc.publisherQuintessence Publishingko_KR
dc.subject1 alpha,25-dihydroxyvitamin D3ko_KR
dc.subjectpoly(D,L-lactide-co-glycolide)ko_KR
dc.subjectanodized titanium implantko_KR
dc.subjecthistomorphometryko_KR
dc.titlePromotion of Osseointegration of Anodized Titanium Implants with a 1 alpha,25-Dihydroxyvitamin D3 Submicron Particle Coatingko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor조영진-
dc.contributor.AlternativeAuthor허성주-
dc.contributor.AlternativeAuthor곽재영-
dc.contributor.AlternativeAuthor김성균-
dc.contributor.AlternativeAuthor이주희-
dc.contributor.AlternativeAuthor이신재-
dc.citation.journaltitleINTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS-
dc.description.tc0-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share