Publications
Detailed Information
저온 혈액희석 체외순환법에 관한 실험적 연구 : An Experimental study on Hemodilution Perfusion with 5% Dextrose Priming under Normothermia, Hypothermia and Profound Hypothermia
Cited 0 time in
Web of Science
Cited 0 time in Scopus
- Authors
- Issue Date
- 1963-12
- Publisher
- 서울대학교 의과대학
- Citation
- Seoul J Med, Vol.4 No.4, pp. 33-67
- Abstract
- Some physiological changes by hemodilution perfusion
with 5% dextrose solution priming under normothermia,
hypothermia and profound hypothermia were
observed in 26 dogs, utilizing bubble type oxygenator.
Pump oxygenator used, was consisted of sigmamotor
pump and two kinds of bubble type oxygenator: small
bag oxygenator for regional perfusion and double
helical oxygenator with new type camste r.
Group I: In 10 dogs, the blood loss during surgery
was replaced by 5% dextrose solution.
Group II: In 8 dogs small bag oxygenator was used
and blood loss replaced by ACD blood.
Group III: In 8 dogs double helical oxygenator was
used and blood loss was replaced by ACD blood.
- ISSN
- 0582-6802
- Language
- Korean
- Files in This Item:
Item View & Download Count