- Abstract
- Carboxyhemoglobin concentrations in 201 patients
admitted to the Seoul National University Hospital
between Jan. 1, 1980 and Dec. 31, 1982 with a diagnosis
of acute carbon monoxide poisoning were determined
with IL-282 CO-Oximeter (Instrumentation
Laboratories Co.). Mean value of carboxyhemoglobin
concentration at admission was 34. 896 and it increased
significantly with the severity of consciousness deterioration.
Using the mathematical model of Jack E. Peterson
et al (Arch Environ Health, 21: 165-171, 1970) for
use in estimating carboxyhemoglobin, the concentra
tion of carbon monoxide to which the patients were
exposed was predicted. Over 75% of patients were
exposed to carbon monoxide at concentrations between
200ppm and 800ppm for 3 to 9 hours