Publications

Detailed Information

Pressure Measurement in Carpal Tunnel Syndrome: Correlation with Electrodiagnostic and Ultrasonographic Findings

DC Field Value Language
dc.contributor.authorAhn, Seong Yeol-
dc.contributor.authorHong, Youn-Ho-
dc.contributor.authorKoh, Young Hwan-
dc.contributor.authorChung, Yeong Seob-
dc.contributor.authorYang, Hee-Jin-
dc.contributor.authorLee, Sang Hyung-
dc.date.accessioned2012-06-13T07:05:50Z-
dc.date.available2012-06-13T07:05:50Z-
dc.date.issued2009-09-
dc.identifier.citationJOURNAL OF KOREAN NEUROSURGICAL SOCIETY; Vol.46 3; 199-204ko_KR
dc.identifier.issn2005-3711-
dc.identifier.urihttps://hdl.handle.net/10371/77035-
dc.description.abstractObjective : This study was done to evaluate the correlation between carpal tunnel pressure (UP), electrodiagnostic and ultrasonographic findings in patients with carpal tunnel syndrome (CTS). Methods : CTP was measured during endoscopic carpal tunnel release (ECTR) for CTS using Spiegelberg ICP monitoring device with parenchymal type catheter. Neurophysiologic severity and nerve cross sectional area were evaluated using nerve conductive study and ultrasonagraphy (USG) before ECTR in all patients. Results : Tests were performed in a total of 48 wrists in 39 patients (9 cases bilateral). Maximum CTP was 56.7 +/- 19.3 mmHg (Mean +/- SD) and 7.4 +/- 3.3 mmHg before and after ECTR, respectively. No correlation was found between maximum CTP and either neurophysiologic severity or nerve cross sectional area, whereas we found a significant correlation between the latter two parameters. Conclusion : CTP was not correlated with neurophysiologic severity and nerve cross sectional area. Dynamic, rather than static, pressure in carpal tunnel might account for the basic pathophysiology of CTS better.ko_KR
dc.language.isoenko_KR
dc.publisherKOREAN NEUROSURGICAL SOCko_KR
dc.subjectCarpal tunnel syndromeko_KR
dc.subjectElectrodiagnosisko_KR
dc.subjectPressureko_KR
dc.subjectUltrasonographyko_KR
dc.titlePressure Measurement in Carpal Tunnel Syndrome: Correlation with Electrodiagnostic and Ultrasonographic Findingsko_KR
dc.typeArticleko_KR
dc.contributor.AlternativeAuthor안성열-
dc.contributor.AlternativeAuthor홍윤호-
dc.contributor.AlternativeAuthor고영환-
dc.contributor.AlternativeAuthor정영섭-
dc.contributor.AlternativeAuthor이상형-
dc.contributor.AlternativeAuthor양희진-
dc.identifier.doi10.3340/jkns.2009.46.3.199-
dc.citation.journaltitleJOURNAL OF KOREAN NEUROSURGICAL SOCIETY-
dc.description.citedreferencePadua L, 2008, CLIN NEUROPHYSIOL, V119, P2064, DOI 10.1016/j.clinph.2008.05.004-
dc.description.citedreferenceHobson-Webb LD, 2008, CLIN NEUROPHYSIOL, V119, P1353, DOI 10.1016/j.clinph.2008.01.101-
dc.description.citedreferenceKaymak B, 2008, ARCH PHYS MED REHAB, V89, P743, DOI 10.1016/j.apmr.2007.09.041-
dc.description.citedreferenceAROORI S, 2008, ULSTER MED J, V77, P6-
dc.description.citedreferenceBayrak IK, 2007, MUSCLE NERVE, V35, P344, DOI 10.1002/mus.20698-
dc.description.citedreferenceIkeda K, 2006, J HAND SURG-AM, V31A, P925, DOI 10.1016/j.jhsa.2006.03.004-
dc.description.citedreferencePARK SK, 2006, J KOREAN NEUROSURG S, V40, P401-
dc.description.citedreferenceKoyuncuoglu HR, 2005, EUR J RADIOL, V56, P365, DOI 10.1016/j.ejrad.2005.05.013-
dc.description.citedreferenceSanz J, 2005, J HAND SURG-BRIT EUR, V30B, P611-
dc.description.citedreferenceLee CH, 2005, ANN PLAS SURG, V54, P20, DOI 10.1097/01.sap.0000141942.27182.55-
dc.description.citedreferenceKANTA M, 2005, ROZHL CHIR, V84, P253-
dc.description.citedreferenceOKUTSU I, 2004, TECH HAND UP EXTREM, V8, P124-
dc.description.citedreferenceNakamichi KI, 2002, MUSCLE NERVE, V26, P798, DOI 10.1002/mus.10276-
dc.description.citedreferenceSchuind F, 2002, J HAND SURG-AM, V27A, P1019, DOI 10.1053/jhsu.2002.36541-
dc.description.citedreferenceSekiya H, 2002, INT ORTHOP, V26, P274, DOI 10.1007/s00264-002-0366-0-
dc.description.citedreferenceOkutsu I, 2001, J HAND SURG-BRIT EUR, V26, P155-
dc.description.citedreferenceKeir PJ, 1999, ERGONOMICS, V42, P1350-
dc.description.citedreferenceLuchetti R, 1998, J HAND SURG-BRIT EUR, V23B, P598-
dc.description.citedreferenceNakao E, 1998, J HAND SURG-AM, V23A, P43-
dc.description.citedreferenceRempel D, 1998, J HAND SURG-AM, V23A, P38-
dc.description.citedreferencePadua L, 1997, ACTA NEUROL SCAND, V96, P211-
dc.description.citedreferenceHashizume H, 1997, ACTA MED OKAYAMA, V51, P105-
dc.description.citedreferenceWerner R, 1997, CLIN BIOMECH, V12, P44-
dc.description.citedreferenceLUCHETTI R, 1990, MUSCLE NERVE, V13, P1164-
dc.description.citedreferenceROJVIROJ S, 1990, J BONE JOINT SURG BR, V72, P516-
dc.description.citedreferenceLUCHETTI R, 1989, ACTA ORTHOP SCAND, V60, P397-
dc.description.citedreferenceSZABO RM, 1989, J HAND SURG-AM, V14A, P624-
dc.description.citedreferenceOKUTSU I, 1989, J BONE JOINT SURG AM, V71A, P679-
dc.description.citedreferenceGELBERMAN RH, 1983, CLIN ORTHOP RELAT R, P285-
dc.description.citedreferenceWERNER CO, 1983, ACTA ORTHOP SCAND, V54, P312-
dc.description.citedreferenceSZABO RM, 1983, J ORTHOPAED RES, V1, P172-
dc.description.citedreferenceGELBERMAN RH, 1981, J BONE JOINT SURG AM, V63, P380-
dc.description.citedreferenceBRAIN WR, 1947, LANCET, V1, P277-
dc.description.tc2-