Publications

Detailed Information

A triangle study of human, instrument and bioelectronic nose for non-destructive sensing of seafood freshness

DC Field Value Language
dc.contributor.authorLee, Kyung Mi-
dc.contributor.authorSon, Manki-
dc.contributor.authorKang, Ju Hee-
dc.contributor.authorKim, Daesan-
dc.contributor.authorHong, Seung Hun-
dc.contributor.authorPark, Tai Hyun-
dc.contributor.authorChun, Hyang Sook-
dc.contributor.authorChoi, Shin Sik-
dc.creator박태현-
dc.date.accessioned2019-04-25T02:06:47Z-
dc.date.available2020-04-05T02:06:47Z-
dc.date.created2018-06-07-
dc.date.issued2018-01-
dc.identifier.citationScientific Reports, Vol.8 No.1, p. 547-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://hdl.handle.net/10371/150213-
dc.description.abstract© 2018 The Author(s). Because the freshness of seafood determines its consumer preference and food safety, the rapid monitoring of seafood deterioration is considered essential. However, the conventional analysis of seafood deterioration using chromatography instruments and bacterial colony counting depends on time-consuming and food-destructive treatments. In this study, we demonstrate a non-destructive and rapid food freshness monitoring system by a triangular study of sensory evaluation, gas chromatography-mass spectroscopy (GC-MS), and a bioelectronic nose. The sensory evaluation indicated that the acceptability and flavor deteriorated gradually during post-harvest storage (4 °C) for 6 days. The GC-MS analysis recognized the reduction of freshness by detecting a generation of dimethyl sulfide (DMS) from the headspace of oyster in a refrigerator (4 °C) at 4 days post-harvest. However, the bioelectronic nose incorporating human olfactory receptor peptides with the carbon nanotube field-effect transistor sensed trimethylamine (TMA) from the oyster at 2 days post-harvest with suggesting early recognition of oysters' quality and freshness deterioration. Given that the bacterial species producing DMS or TMA along with toxins were found in the oyster, the bacterial contamination-driven food deterioration is rapidly monitored using the bioelectronic nose with a targeted non-destructive freshness marker.-
dc.language영어-
dc.language.isoenen
dc.publisherNature Publishing Group-
dc.titleA triangle study of human, instrument and bioelectronic nose for non-destructive sensing of seafood freshness-
dc.typeArticle-
dc.identifier.doi10.1038/s41598-017-19033-y-
dc.citation.journaltitleScientific Reports-
dc.identifier.wosid000419942100030-
dc.identifier.scopusid2-s2.0-85040465566-
dc.description.srndOAIID:RECH_ACHV_DSTSH_NO:T201824449-
dc.description.srndRECH_ACHV_FG:RR00200001-
dc.description.srndADJUST_YN:-
dc.description.srndEMP_ID:A002014-
dc.description.srndCITE_RATE:4.122-
dc.description.srndFILENAME:2. (2018.01) A triangle study of human, instrument and (8; 547).pdf-
dc.description.srndDEPT_NM:화학생물공학부-
dc.description.srndEMAIL:thpark@snu.ac.kr-
dc.description.srndSCOPUS_YN:Y-
dc.description.srndFILEURL:https://srnd.snu.ac.kr/eXrepEIR/fws/file/df72ab6d-09cd-4da6-917b-cd1128149aea/link-
dc.citation.number1-
dc.citation.startpage547-
dc.citation.volume8-
dc.description.isOpenAccessY-
dc.contributor.affiliatedAuthorHong, Seung Hun-
dc.contributor.affiliatedAuthorPark, Tai Hyun-
dc.identifier.srndT201824449-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusCHROMATOGRAPHY-MASS-SPECTROMETRY-
dc.subject.keywordPlusSOLID-PHASE MICROEXTRACTION-
dc.subject.keywordPlusVOLATILE PROFILE CHARACTERISTICS-
dc.subject.keywordPlusOYSTERS CRASSOSTREA-GIGAS-
dc.subject.keywordPlusSPME-GC-MS-
dc.subject.keywordPlusSPOILAGE INDICATORS-
dc.subject.keywordPlusSTORAGE-
dc.subject.keywordPlusFISH-
dc.subject.keywordPlusINFECTIONS-
dc.subject.keywordPlusSHELLFISH-
Appears in Collections:
Files in This Item:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share