Publications

Detailed Information

Sensors in heart-on-a-chip: A review on recent progress

DC Field Value Language
dc.contributor.authorCho, Kyoung Won-
dc.contributor.authorLee, Wang Hee-
dc.contributor.authorKim, Byung-Soo-
dc.contributor.authorKim, Dae-Hyeong-
dc.date.accessioned2021-01-29T06:48:15Z-
dc.date.available2021-01-29T06:48:15Z-
dc.date.created2020-10-05-
dc.date.created2020-10-05-
dc.date.created2020-10-05-
dc.date.issued2020-11-01-
dc.identifier.citationTalanta, Vol.219, p. 121269-
dc.identifier.issn0039-9140-
dc.identifier.other112640-
dc.identifier.urihttps://hdl.handle.net/10371/171736-
dc.description.abstractDrug-induced cardiotoxicity is a major problem in drug discovery. Many approaches to efficient drug screening have been developed, including animal testing in vivo and cell testing in vitro. However, due to intrinsic difference between species, animal-based toxicity testing cannot comprehensively determine the potential side effects in subsequent human clinical trials. Furthermore, conventional in vitro assays are costly and labour intensive, and require numerous tests. Therefore, it would be necessary to develop heart-on-a-chips made with advanced materials and soft bioelectronic fabrication techniques that offer fast, efficient, and accurate sensing of cardiac cells' behaviors in vitro. In this review, we introduce two key sensing methods in heart-on-a-chip for physical and electrical measurements. First, optical (e.g., direct and calcium imaging, and fluorescent, laser-based, and colorimetric sensing) and electrical (e.g., impedance, strain, and crack sensing) sensors that record the contractility of cardiomyocytes are reviewed. Subsequently, various sensors composed of rigid planar/three-dimensional electrodes, soft/flexible electronics, and nanomaterial-based transistors to monitor extracellular and intracellular electrophysiological potentials are discussed. A brief overview of future technology and comments on the current challenges conclude the review.-
dc.language영어-
dc.publisherElsevier BV-
dc.titleSensors in heart-on-a-chip: A review on recent progress-
dc.typeArticle-
dc.contributor.AlternativeAuthor김대형-
dc.contributor.AlternativeAuthor김병수-
dc.identifier.doi10.1016/j.talanta.2020.121269-
dc.citation.journaltitleTalanta-
dc.identifier.wosid000568747200006-
dc.identifier.scopusid2-s2.0-85086834429-
dc.citation.startpage121269-
dc.citation.volume219-
dc.identifier.sci000568747200006-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorKim, Byung-Soo-
dc.contributor.affiliatedAuthorKim, Dae-Hyeong-
dc.type.docTypeReview-
dc.description.journalClass1-
dc.subject.keywordPlusCELL-DERIVED CARDIOMYOCYTES-
dc.subject.keywordPlusHIGH-THROUGHPUT-
dc.subject.keywordPlusACTION-POTENTIALS-
dc.subject.keywordPlusSTEM-CELLS-
dc.subject.keywordPlusSTRETCHABLE ELECTRONICS-
dc.subject.keywordPlusCARDIAC-CELLS-
dc.subject.keywordPlusSCAFFOLDS-
dc.subject.keywordPlusCULTURE-
dc.subject.keywordPlusDIFFERENTIATION-
dc.subject.keywordPlusGRAPHENE-
dc.subject.keywordAuthorHeart-on-a-chip-
dc.subject.keywordAuthorFlexible electronics-
dc.subject.keywordAuthorBiosensors-
dc.subject.keywordAuthorDrug screening-
dc.subject.keywordAuthorElectrophysiology-
Appears in Collections:
Files in This Item:

Related Researcher

  • College of Engineering
  • School of Chemical and Biological Engineering
Research Area Materials Science

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share