Publications

Detailed Information

Blip up-down acquisition for spin- and gradient-echo imaging (BUDA-SAGE) with self-supervised denoising enables efficient T-2, T-2, para- and dia-magnetic susceptibility mapping

DC Field Value Language
dc.contributor.authorZhang, Zijing-
dc.contributor.authorCho, Jaejin-
dc.contributor.authorWang, Long-
dc.contributor.authorLiao, Congyu-
dc.contributor.authorShin, Hyeong-Geol-
dc.contributor.authorCao, Xiaozhi-
dc.contributor.authorLee, Jongho-
dc.contributor.authorXu, Jinmin-
dc.contributor.authorZhang, Tao-
dc.contributor.authorYe, Huihui-
dc.contributor.authorSetsompop, Kawin-
dc.contributor.authorLiu, Huafeng-
dc.contributor.authorBilgic, Berkin-
dc.date.accessioned2022-10-12T01:12:08Z-
dc.date.available2022-10-12T01:12:08Z-
dc.date.created2022-08-17-
dc.date.issued2022-08-
dc.identifier.citationMagnetic Resonance in Medicine, Vol.88 No.2, pp.633-650-
dc.identifier.issn0740-3194-
dc.identifier.urihttps://hdl.handle.net/10371/185939-
dc.description.abstractPurpose To rapidly obtain high resolution T-2, T-2*, and quantitative susceptibility mapping (QSM) source separation maps with whole-brain coverage and high geometric fidelity. Methods We propose Blip Up-Down Acquisition for Spin And Gradient Echo imaging (BUDA-SAGE), an efficient EPI sequence for quantitative mapping. The acquisition includes multiple T-2*-, T-2 '-, and T-2-weighted contrasts. We alternate the phase-encoding polarities across the interleaved shots in this multi-shot navigator-free acquisition. A field map estimated from interim reconstructions was incorporated into the joint multi-shot EPI reconstruction with a structured low rank constraint to eliminate distortion. A self-supervised neural network (NN), MR-Self2Self (MR-S2S), was used to perform denoising to boost SNR. Using Slider encoding allowed us to reach 1 mm isotropic resolution by performing super-resolution reconstruction on volumes acquired with 2 mm slice thickness. Quantitative T-2 (=1/R-2) and T-2* (=1/R-2*) maps were obtained using Bloch dictionary matching on the reconstructed echoes. QSM was estimated using nonlinear dipole inversion on the gradient echoes. Starting from the estimated R-2/R-2* maps, R-2 ' information was derived and used in source separation QSM reconstruction, which provided additional para- and dia-magnetic susceptibility maps. Results In vivo results demonstrate the ability of BUDA-SAGE to provide whole-brain, distortion-free, high-resolution, multi-contrast images and quantitative T-2/T-2* maps, as well as yielding para- and dia-magnetic susceptibility maps. Estimated quantitative maps showed comparable values to conventional mapping methods in phantom and in vivo measurements. Conclusion BUDA-SAGE acquisition with self-supervised denoising and Slider encoding enables rapid, distortion-free, whole-brain T-2/T-2* mapping at 1 mm isotropic resolution under 90 s.-
dc.language영어-
dc.publisherJohn Wiley & Sons Inc.-
dc.titleBlip up-down acquisition for spin- and gradient-echo imaging (BUDA-SAGE) with self-supervised denoising enables efficient T-2, T-2, para- and dia-magnetic susceptibility mapping-
dc.typeArticle-
dc.identifier.doi10.1002/mrm.29219-
dc.citation.journaltitleMagnetic Resonance in Medicine-
dc.identifier.wosid000783723000001-
dc.identifier.scopusid2-s2.0-85128258820-
dc.citation.endpage650-
dc.citation.number2-
dc.citation.startpage633-
dc.citation.volume88-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorLee, Jongho-
dc.type.docTypeArticle-
dc.description.journalClass1-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share