Publications

Detailed Information

Bayesian Optimization of Soft Exosuits Using a Metabolic Estimator Stopping Process

DC Field Value Language
dc.contributor.authorKim, Myunghee-
dc.contributor.authorLiu, Charles-
dc.contributor.authorKim, Jinsoo-
dc.contributor.authorLee, Sangjun-
dc.contributor.authorMeguid, Adham-
dc.contributor.authorWalsh, Conor J.-
dc.contributor.authorKuindersma, Scott-
dc.date.accessioned2024-05-09T05:34:19Z-
dc.date.available2024-05-09T05:34:19Z-
dc.date.created2024-05-09-
dc.date.issued2019-
dc.identifier.citation2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), pp.9173-9179-
dc.identifier.issn1050-4729-
dc.identifier.urihttps://hdl.handle.net/10371/201343-
dc.description.abstractRecent human-in-the-loop (HIL) optimization studies using wearable devices have shown an improved average metabolic reduction by optimizing a small number of control parameters during short-duration walking experiments. However, the slow metabolic dynamics, high measurement noise, and experimental time constraints create challenges for increasing the number of control parameters to be optimized. Prior work applying gradient descent and Bayesian optimization to this problem have decoupled metabolic estimation and control parameter selection using fixed estimation intervals, which imposes a hard limit on the number of parameter evaluations possible in a given time budget. In this work, we take a different approach that couples estimation and parameter selection, allowing the algorithm to spend less time on refining the metabolic estimates for parameters that are unlikely to improve performance over the best observed values. Our approach uses a Kalman filter-based metabolic estimator to formulate an optimal stopping problem during the data acquisition step of standard Bayesian optimization. Performance was analyzed in numerical simulations and in pilot human subject testing with two subjects that involved optimizing six control parameters of a single-joint exosuit and four parameters of a multi-joint exosuit.-
dc.language영어-
dc.publisherIEEE-
dc.titleBayesian Optimization of Soft Exosuits Using a Metabolic Estimator Stopping Process-
dc.typeArticle-
dc.identifier.doi10.1109/icra.2019.8793817-
dc.citation.journaltitle2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA)-
dc.identifier.wosid000494942306107-
dc.identifier.scopusid2-s2.0-85071466016-
dc.citation.endpage9179-
dc.citation.startpage9173-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorKim, Jinsoo-
dc.type.docTypeProceedings Paper-
dc.description.journalClass1-
dc.subject.keywordPlusASSISTANCE-
dc.subject.keywordPlusCOST-
dc.subject.keywordPlusLOOP-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Engineering
  • Department of Electrical and Computer Engineering
Research Area Biomechanics, Exoskeleton, Robotics, 로보틱스, 생체역학, 엑소스켈레톤

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share