Publications

Detailed Information

Comparative cost and performance of light-emitting diode microscopy in HIV-tuberculosis-co-infected patients

Cited 25 time in Web of Science Cited 29 time in Scopus
Authors

Whitelaw, A.; Peter, J.; Sohn, H.; Viljoen, D.; Theron, G.; Badri, M.; Davids, V.; Pai, M.; Dheda, K.

Issue Date
2011-12
Publisher
EUROPEAN RESPIRATORY SOC JOURNALS LTD
Citation
EUROPEAN RESPIRATORY JOURNAL, Vol.38 No.6, pp.1393-1397
Abstract
Light-emitting diode (LED) microscopy has recently been endorsed by the World Health Organization (WHO). However, it is unclear whether LED is as accurate and cost-effective as Ziehl-Neelsen (ZN) microscopy or mercury vapour fluorescence microscopy (MVFM) in tuberculosis (TB)-HIV-co-infected subjects. Direct and concentrated sputum smears from TB suspects were evaluated using combinations of LED microscopy, ZN microscopy and MVFM. Median reading time per slide was recorded and a cost analysis performed. Mycobacterial culture served as the reference standard. 647 sputum samples were obtained from 354 patients (88 (29.8%) were HIV-infected and 161 (26%) were culture-positive for Mycobacterium tuberculosis). Although overall sensitivity of LED compared with ZN microscopy or MVFM was similar, sensitivity of all three modalities was lower in HIV-infected patients. In the HIV-infected group, the sensitivity of LED microscopy was higher than ZN microscopy using samples that were not concentrated (46 versus 39%; p=0.25), and better than MVFM using concentrated samples (56 versus 44; p=0.5). A similar trend was seen in the CD4 count <200 cells.mL(-1) subgroup. Median (interquartile range) reading time was quicker with LED compared with ZN microscopy (1.8 (1.7-1.9) versus 2.5 (2.2-2.7) min; p <= 0.001). Average cost per slide read was less for LED microscopy (US$1.63) compared with ZN microscopy (US$2.10). Among HIV-TB-co-infected patients, LED microscopy was cheaper and performed as well as ZN microscopy or MVFM independent of the staining (ZN or auramine O) or processing methods used.
ISSN
0903-1936
URI
https://hdl.handle.net/10371/201773
DOI
https://doi.org/10.1183/09031936.00023211
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Human Systems Medicine
Research Area 결핵, 국제보건, 에이즈

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share