Publications

Detailed Information

In vivo biocompatibilty and degradation behavior of elastic poly(L-lactide-co-epsilon-caprolactone) scaffolds : In vivo biocompatibilty and degradation behavior of elastic poly(L-lactide-co-ε-caprolactone) scaffolds

DC Field Value Language
dc.contributor.authorSung In Jeong-
dc.contributor.authorByung-Soo Kim-
dc.contributor.authorSun Woong Kang-
dc.contributor.authorJae Hyun Kwon-
dc.contributor.authorYoung Moo Lee-
dc.contributor.authorSoo Hyun Kim-
dc.contributor.authorYoung Ha Kim-
dc.date.accessioned2024-06-13T02:23:26Z-
dc.date.available2024-06-13T02:23:26Z-
dc.date.created2018-06-18-
dc.date.created2018-06-18-
dc.date.issued2004-12-
dc.identifier.citationBIOMATERIALS, Vol.25 No.28, pp.5939-5946-
dc.identifier.issn0142-9612-
dc.identifier.urihttps://hdl.handle.net/10371/204441-
dc.description.abstractTubular scaffolds were fabricated from very elastic poly(L-lactide-co-epsilon-caprolactone) (PLCL, 50:50). The scaffolds were seeded with smooth muscle cells (SMCs) and implanted in nude mice to investigate the tissue compatibility and in vivo degradation behavior. Histological examination of all the implants with haematoxylin and eosin staining, masson trichrome staining, SM alpha-actin antibody, and CM-DiI labeling confirmed that the regular morphology and biofunction of the SMCs seeded and the expression of the vascular smooth muscle matrices in PLCL scaffolds. The implanted PLCL scaffolds displayed a slow degradation on time, where caprolactone units were faster degraded than lactide did. This could be explained by the fact that amorphous regions composed of mainly CL moieties degraded earlier than hard domains where most of the LA units were located. From these results, the scaffolds applied in this study were found to exhibit excellent tissue compatibility to SMCs and might be very useful for vascular tissue engineering. (C) 2004 Elsevier Ltd. All rights reserved.-
dc.language영어-
dc.publisherELSEVIER SCI LTD-
dc.titleIn vivo biocompatibilty and degradation behavior of elastic poly(L-lactide-co-epsilon-caprolactone) scaffolds-
dc.title.alternativeIn vivo biocompatibilty and degradation behavior of elastic poly(L-lactide-co-ε-caprolactone) scaffolds-
dc.typeArticle-
dc.identifier.doi10.1016/j.biomaterials.2004.01.057-
dc.citation.journaltitleBIOMATERIALS-
dc.identifier.wosid000223208400004-
dc.identifier.scopusid2-s2.0-2942607678-
dc.citation.endpage5946-
dc.citation.number28-
dc.citation.startpage5939-
dc.citation.volume25-
dc.description.isOpenAccessN-
dc.contributor.affiliatedAuthorByung-Soo Kim-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.subject.keywordPlusSMOOTH-MUSCLE-CELLS-
dc.subject.keywordPlusEPSILON-CAPROLACTONE-
dc.subject.keywordPlusL-LACTIDE-
dc.subject.keywordPlusCOPOLYMERS-
dc.subject.keywordPlusCOLLAGEN-
dc.subject.keywordPlusBLOCK-
dc.subject.keywordAuthorelastic PLCL scaffolds-
dc.subject.keywordAuthorcompatibility to smooth muscle cells-
dc.subject.keywordAuthorbiodegradation-
Appears in Collections:
Files in This Item:
There are no files associated with this item.

Related Researcher

  • College of Engineering
  • School of Chemical and Biological Engineering
Research Area biomaterials, nanomedicine, regenerative medicine

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share