Publications

Detailed Information

Software performance in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas

Cited 37 time in Web of Science Cited 42 time in Scopus
Authors

Cohen, Julien G.; Goo, Jin Mo; Yoo, Roh-Eul; Park, Chang Min; Lee, Chang Hyun; van Ginneken, Bram; Chung, Doo Hyun; Kim, Young Tae

Issue Date
2016-12
Publisher
Springer Verlag
Citation
European Radiology, Vol.26 No.12, pp.4465-4474
Abstract
To evaluate the performance of software in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas. Seventy-three pulmonary adenocarcinomas manifesting as subsolid nodules were included. Two radiologists measured the maximal axial diameter of the ground-glass components on lung windows and that of the solid components on lung and mediastinal windows. Nodules were segmented using software by applying five (-850 HU to -650 HU) and nine (-130 HU to -500 HU) attenuation thresholds. We compared the manual and software measurements of ground-glass and solid components with pathology measurements of tumour and invasive components. Segmentation of ground-glass components at a threshold of -750 HU yielded mean differences of +0.06 mm (p = 0.83, 95 % limits of agreement, 4.51 to 4.67) and -2.32 mm (p < 0.001, -8.27 to 3.63) when compared with pathology and manual measurements, respectively. For solid components, mean differences between the software (at -350 HU) and pathology measurements and between the manual (lung and mediastinal windows) and pathology measurements were -0.12 mm (p = 0.74, -5.73 to 5.55]), 0.15 mm (p = 0.73, -6.92 to 7.22), and -1.14 mm (p < 0.001, -7.93 to 5.64), respectively. Software segmentation of ground-glass and solid components in subsolid nodules showed no significant difference with pathology. aEuro cent Software can effectively segment ground-glass and solid components in subsolid nodules. aEuro cent Software measurements show no significant difference with pathology measurements. aEuro cent Manual measurements are more accurate on lung windows than on mediastinal windows.
ISSN
0938-7994
URI
https://hdl.handle.net/10371/206824
DOI
https://doi.org/10.1007/s00330-016-4317-3
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Related Researcher

  • College of Medicine
  • Department of Medicine
Research Area Radiology

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share