경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구 : Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model

Cited 0 time in Web of Science Cited 0 time in Scopus
Authors

이혁재; 김창회; 임영준; 김명주

Issue Date
2008
Publisher
대한치과보철학회
Citation
2008;46:2
Keywords
Implant impressionAngulationAbutmentCementation
Abstract
Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 () and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 () was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 () did not differ significantly from resin splinted open tray technique;50.3 (). (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.
ISSN
0301-2875
Language
Korean
URI
https://hdl.handle.net/10371/47325
Files in This Item:
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share